Vanguard Heating VMH26PRA Connecting Fireplace to GAS Supply, Installation Items Needed

Models: VMH26PRA

1 30
Download 30 pages 45.19 Kb
Page 14
Image 14

® VMH26PRA

COMPACT CLASSIC HEARTH FIREPLACE

INSTALLATION

Continued

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

Phillips screwdriver

sealant (resistant to propane/LP gas, not provided)

1.Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.

2.Remove screws that attach branch sup- port to fireplace (see Figure 24). Care- fully lift up branch support and remove from fireplace (see Figure 24).

3.Route flexible gas line (provided by installer) from equipment shutoff valve into fireplace through side or rear ac- cess holes in outer casing. Route flex- ible gas supply line through fireplace access holes in outer casing.

CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

Shoulder

Screw

Screen

Branch

Support

Figure 24 - Removing Branch Support From Fireplace

NOTICE: Most building codes do not permit concealed gas con- nections. A flexible gas line (see Figure 25) is provided to allow accessibility from the fireplace. The flexible gas supply line con- nection to the equipment shutoff valve should be accessible.

4. Apply pipe joint sealant lightly to male

threads of gas connector attached to

flexible gas line (see Figure 25). Con-

Equipment shutoff valve

To Gas

Supply

 

Gas Connector

To Fireplace

Gas Valve

 

Flexible Gas Line from

Flexible Gas Line from

Equipment Shutoff Valve

Fireplace Gas Valve

Provided by Installer

Provided with Fireplace

nect flexible gas line to flexible gas line

attached to gas valve of fireplace (see

Figure 25).

5. Check all gas connections for leaks. See

Checking Gas Connections, page 15.

6. Replace branch support back into fire-

place. Feed flexible gas line into fire-

place base area while replacing branch

support. Make sure the entire flexible

gas line is in fireplace base area. Reat-

tach branch support to fireplace with

screws removed in step 2.

Figure 25 - Attaching Flexible Gas Lines Together

For more information, visit www.desatech.com

14

107034

Page 14
Image 14
Vanguard Heating VMH26PRA installation manual Connecting Fireplace to GAS Supply, Installation Items Needed