Vanguard Heating VMH26PRA installation manual Optional Wall Switch GWMS2

Models: VMH26PRA

1 30
Download 30 pages 45.19 Kb
Page 17
Image 17

OWNER’S MANUAL

INSTALLATION

Continued

6.Connect one bare wire end to each ter- minal (“W” and “R”) of the thermostat base (see Figure 35).

7.Install the base onto the wall with the provided screws.

8.Move the temperature adjustment back and forth to insure the bimetal is free from restrictions.

9.Replace the cover onto the base. (Upon installation, the thermostat must be al- lowed to stabilize at room temperature for a minimum of 30 minutes for proper operation).

10.Set switch on heater to Auto position.

11.Set the temperature adjustment to the desired setting. This thermostat has been electronically calibrated at the factory. No adjustment or leveling is necessary.

Terminal “W”

W

Terminal “R”

R

Figure 35 - Thermostat Base Terminals “W” and “R”

OPTIONAL WALL SWITCH - GWMS2

WARNING: Read and follow installation instructions. Instal- lation should be done by a quali- fied installer familiar with low- voltage wiring procedures.

WARNING: Do not connect this switch to any electrical source! Electrical shock and/or fire hazard will occur.

1.

Connect one terminal of 25 ft. wire to

 

bottom contact of switch (see Figure 33).

2.

Connect remaining wire terminal to the

 

“TH” terminal on the control valve.

 

Make sure that wire terminals are in

 

the positions on your unit as pictured

 

in Figure 33. If wires are not “crossed”

 

the thermostat will not work.

3.

Route the 25 ft. wire to a convenient

 

location to mount your wall switch (no

Switch on Gas

Control

Heater

Valve

AUTO

 

OFF

 

ON

To Wall

One

terminal of

Thermostat

25 ft. wire

or Switch

Figure 33 - Connecting Wire Terminals

Feed wires through rectangular slots

To Wall Thermostat or Switch

outside walls).

WARNING: Do not connect the switch to a power source. Electrical shock and/or fire haz- ard will occur.

IMPORTANT: The wire may be shortened but must not be lengthened.

4.Connect one bare wire end to each of the terminals of the provided wall switch.

5.Install the wall switch and cover in the wall.

Figure 34 - Back View of Thermostat Base

107034

17

For more information, visit www.desatech.com

Page 17
Image 17
Vanguard Heating VMH26PRA installation manual Optional Wall Switch GWMS2