® VMH26PRA
COMPACT CLASSIC HEARTH FIREPLACE
OPERATING
FIREPLACE
Continued
IMPORTANT: This remote control has been specially engineered to take an air temperature sample every 5.5 minutes in the auto mode. It will not respond immediately to the tempera- ture setting being turned up or down.
IMPORTANT: The
3.To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit.
IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.
Shows | Increases Room |
Temperature in | |
Temperature | AUTO Mode |
Setting |
|
Decreases
Room
Temperature
in AUTO
Mode
The Log Heater | Turns Burners | |
will Automatically | ||
On or Off and | ||
Cycle between | ||
Allows You to | ||
Pilot and the Heat | ||
Choose the | ||
Setting that has | ||
Auto Setting | ||
been Selected | ||
|
Figure 39 - Thermostat Hand-Held
Remote Control Unit Selections
(GHRCTA Series Only)
GWMT1 WALL
MOUNTED
THERMOSTAT
(OPTIONAL)
Make sure the heater switch is on AUTO and set the temperature adjustment on wall thermostat to the desired setting. The thermostat has been electronically calibrated at the factory and requires no adjustment or leveling.
Upon installation, the thermostat must be allowed to stabilize at room tempera- ture for a minimum of 30 minutes for proper operation. See installation instruc- tions on pages 16 and 17 of this manual.
GWMS2 WALL
MOUNTED SWITCH
(OPTIONAL)
Make sure the heater switch is on AUTO. This wall switch works just like the con- ventional light switch. Flip the switch up for on and down for off.
Note: Make sure that this switch is not in a position to be mistaken for a light switch. This may result in the heater being inad- vertently turned on without the proper precautions being taken. See installation instructions on page 17 of this manual.
OPERATING BLOWER
This blower has three settings: ON, OFF, and AUTO. In the ON position, the blower will operate constantly. In the OFF posi- tion, the blower will not operate. In the AUTO position, the blower will start when the thermostat senses a sufficient increase in firebox temperature.
Note: Your fireplace and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.
Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fireplace.
Auto/Off/On Switch
Figure 40 - Auto/Off/On Switch
INSPECTING
BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 41 shows a correct pilot flame pat- tern. Figure 42 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. When the thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 42.
•turn heater off (see To Turn Off Gas to Appliance, page 19)
•see Troubleshooting, pages 22 through 24
Pilot Burner
Thermocouple
Figure 41 - Correct Pilot Flame Pattern
Pilot Burner
Thermocouple
Figure 42 - Incorrect Pilot Flame Pattern
For more information, visit www.desatech.com | 20 | 107034 |