OWNER’S MANUAL
OPERATING
FIREPLACE
Continued
Pilot Burner
Ignitor
Electrode
Figure 37 - Pilot
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1.Turn control knob clockwise to the OFF position.
2a. Set selector switch in the OFF position.
2b. If Using Optional
Shutting Off Burner Only (pilot stays lit)
You may shut off the burner and keep the pilot lit by doing one of the following:
•Turn control knob clockwise to the PILOT position.
•Use remote control manual OFF button.
•Set selector switch in the OFF position.
MANUAL LIGHTING
PROCEDURE
1. | Follow steps 1 through 6 under Light- |
| ing Instructions, page 18. |
2. | Depress control knob and light pilot |
| with match. |
3. | Keep control knob pressed in for 30 |
OPTIONAL REMOTE
OPERATION
Note: All remote control accessories must be purchased separately (see Accessories, pages 28 and 29). Follow installation in- structions on page 16 of this manual.
Thermostat Control Operation
(Optional GHRCTA Series Only) The thermostat control setting on the remote control unit can be set to any comfort level between WARMER and COOLER. The burner will turn on and off automatically to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the cen- tral heating system, etc.
For wall thermostat operation, follow in- struction supplied with thermostat acces- sory GWMT1. For wall switch operation follow instructions supplied with GWMS2.
NOTICE: You must light the pilot before using the
1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjust- ment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position. Note: The burner may light if
IMPORTANT: Do not leave the se- lector switch in the REMOTE posi- tion when the pilot is not lit. This will drain the battery.
IMPORTANT: Be sure to press the ON/OFF buttons on the hand held remote control unit for up to 3 sec- onds to assure proper operation.
GHRC Series Operation:
2a. Press the ON/OFF button to turn the burner on and off. When turning burner off, the pilot will remain lit.
GHRCTA Series Operation:
2b. Press the AUTO/ON/OFF button on the
•In the ON mode, the burners will ignite. The heater is in manual mode when ON is lit.
•In the AUTO mode, the thermostat in the
seconds after lighting pilot. After 30 |
seconds, release control knob. Now |
follow steps 9 through 11, page 18. |
| Control Knob |
| Flame Adjustment Knob | |
|
|
|
| |
REMOTE |
|
|
| OL |
N |
|
|
| |
OFF |
|
|
| |
O |
| F O |
| |
ON | T |
|
| |
| O |
| F |
|
| L |
| HI | |
|
| IP |
|
Selector Switch in Remote
Position (Optional Remote Control)
Figure 38 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation
Continued
107034 | 19 | For more information, visit www.desatech.com |