® VMH26PRA
COMPACT CLASSIC HEARTH FIREPLACE
INSTALLATION
Continued
8. Reconnect red wire to switch position |
3. Reconnect blue wire to switch posi- |
tion 1. Reconnect green and white wires. |
9. Install the switch plate on the valve cover |
shield with 2 #10 screws provided (see |
Figure 17). Route power cord out of the |
cabinet by inserting it through the bush- |
ing on the outer casing (see Figure 16, |
page 11). Plug fan kit into |
grounded power supply and test opera- |
tion. Note: When switch is in the AUTO |
position, the fan will start after the heater |
has run for a few moments. The fan will |
continue to run for several moments af- |
ter the heater has been turned off. When |
1.Install a snap bushing found in hard- ware kit into one of the holes found rear of valve cover shield. The other hole is for a strain relief clamp (not supplied) to secure incoming electrical supply.
2.Follow steps 2 through 6 in Installing Blower Assembly, page 11.
3.A licensed electrician must follow the wiring diagram to connect incoming electrical supply to fan kit wiring har- ness (see Figure 19).
4.Plug power cord to the outlet receptacle (not provided) as shown in Figure 20. Wind the extra cable in power cord and and tie it up with the plastic wire strap
Fan Switch
(Auto/Off/On)
1 Auto
(see Figure 20). Set the cable bundle between the burner bracket and outer casing, away from the burner.
5.Test to make sure the blower is work- ing properly.
6.Reinstall upper louver assembly (see Fig- ure 15, page 11) and close lower louver.
Extension Cord
Use extension cord if needed. The cord must have a
switch is in the ON position, the fan will |
run until turned to OFF. Reinstall upper |
louver assembly (see Figure 15, page 11) |
and branch support. Close lower louver |
door. |
Valve Cover
Shield
| Off | 2 |
|
|
|
|
|
|
|
|
|
| 3 | Blue |
| Thermostat | |||||
|
|
| On |
|
|
| Switch | |||
|
|
|
|
| (N.O.) | |||||
110/115 |
|
| Red |
|
|
|
| Blue | ||
V.A.C. |
|
|
|
| Blower | |||||
| Black |
|
|
|
|
|
|
| Motor | |
|
|
|
|
|
| Red |
| |||
| White |
|
|
|
|
| White |
| ||
| Green |
|
|
|
|
| Green |
Figure 19 - Wiring Diagram For Blower Accessory Built-In Installation
Blower Bracket Assembly
Switch Screw
Plate
Figure 17 - Installing Switch Plate to Valve Cover Shield
Fan Switch
(Auto/Off/On)
1Auto
Screw
Wire Harness
|
| Off | 2 |
|
|
| 3 |
|
|
| On |
110/115 | Red | ||
| V.A.C. |
| |
|
| Black |
|
|
|
| |
|
| White |
|
|
| Green |
|
Blue Thermostat
Switch
(N.O.)
Blue
Blower
Motor
Red
White
Green
Switch | Power | Outlet |
Cord | Receptacle | |
| (Not Supplied) | |
|
|
Figure 18 - Wiring Diagram For Blower Accessory Standard Installation
For Built-In Installation
WARNING: A licensed electri- cian must connect the wiring har- ness to electrical supply following all local codes. Electrician must provide a clamp on the box cover to securethewiring.Wiringshouldbe routed through the bushing in the hole on the outer casing of heater.
Blue Red
Switch
Plastic
Wire Wire
Harness Strap
Clamp Connector (not included)
Figure 20 - Installing Blower Bracket Assembly
For more information, visit www.desatech.com | 12 | 107034 |