![](/images/new-backgrounds/1268712/268712109x1.webp)
A
4 – Installation iSR6142 Router Installation
Connect the Router to AC Power
WARNING!!
This product is supplied with a
You may require a different power cable in some countries because the plug on the cable supplied with the equipment will not fit your electrical outlet. In this case, you must supply your own power cable. The cable must meet the following requirements:
For 125 Volt electrical service – the cable must be rated at 10 Amps and be approved by UL and CSA.
For 250 Volt electrical service – the cable must be rated at 10 Amps, meet requirements of
DEMKO.
To power up the router, connect the power cord to the power receptacle on the router chassis and to a grounded AC outlet. The router responds in the following sequence:
1.The chassis LEDs (input power, heartbeat, system fault) light up, then all port LEDs light up.
2.After a couple of seconds the heartbeat and system fault LEDs go off, while the input power LED stays on. The router is executing the POST.
3.The POST completes after about 45 seconds and the heartbeat LED starts flashing at a one second rate. If an error has occurred, the System Fault LED will blink a pattern that indicates the fault reason. For more information about error blink patterns, see page