TRI AMP/BI AMP Switch
TRI AMP: Shading network is NOT applied (shading must be provided by upstream signal processing). Connect the full-range input signal to pins 1+ and 1-, connect the shaded (processed) signal to pins 2+ and
2-. To flip shaded transducer location, use the MF (UNSHADED) SELECT switch or alter signal processing. Default MF (UNSHADED) SELECT switch position for three way mode is position A; if put in position B, connections (Table 1) to LF transducers A and B are interchanged.
BI AMP: The “full-range” LF input is applied to pins 1+ and 1- and the -6 dB per octave shading network is applied to one of the LF transducers using the MF (UNSHADED) SELECT switch.
MF (UNSHADED) SELECT Switch
The WideLine-10 is a 3-way design (shaded, non-shaded and high- frequency) with shading provided by a passive network in BI AMP mode or upstream signal processing (DSP) in TRI AMP mode. This allows switch position selection for use as either “house left” or “house right”, without the need to invert boxes.
BI AMP: The shading switch allows either low-frequency transducer to be selected as the shaded unit (bass only) by inserting a -6 dB per octave network. The switch handle points to the side of the unshaded (full-range) low-frequency transducer.
TRI AMP: The internal -6 dB per octave network is NOT applied to either LF transducer. Shading is accomplished with signal processing. The switch handle points to the side of the non-shaded (full-range)