1Listing and Code Approvals
A. Appliance Certi cation
MODEL: | Castile Gas Stove |
|
|
LABORATORY: | OMNI Test Laboratories, Inc. |
| |
|
|
TYPE: | Direct Vent Gas Heater |
STANDARD: | ANSI |
| UL307b CAN/CBA |
The product is listed to ANSI standards for “Vented Gas Appliance Heaters” and applicable sections of “Gas Burning Heating Appliances for Manufactured Homes and Recre- ational Vehicles” and "Gas Fired Appliances for use at High Altitudes".
Manufactured Home or Mobile Home installation may occur only after the home is site located and must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.
When installed, the appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
C. BTU Speci cations
Model | Maximum | Minimum | Orifi ce | *Efficiency | **P.4 |
(US or Canada) | Input BTU | Input | Size | Up To | % |
|
| BTU | (DMS) |
|
|
Castile Gas | 31,000 | 22,000 | .106 | 81.43 | 57.33 |
Stove |
|
|
|
|
|
(NG) |
|
|
|
|
|
Castile Gas | 30,000 | 23,000 | .063 | 82.75 | 56.41 |
Stove |
|
|
|
|
|
(LP) |
|
|
|
|
|
*Maximum Vent Blower On **Canada Only
D. High Altitude Installations
When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input rating by changing the existing burner orifi ce to a smaller size. Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifi ce size, check with the local gas utility.
If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities.
B. Glass Speci cations
This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass.
E. Non-Combustible Materials
Materials that are reported as passing ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C, shall be considered
NOTE: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI
F. Combustible Materials
Materials made of or surfaced with wood, compressed paper, plant fibers, plastics, or other materials that can ignite and burn, whether flame proofed or not, or whether plastered or unplastered shall be considered combustible materials.
WARNING
Do NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water.
Page 4 | July 29, 2008 |