11 Maintaining and Servicing Your Appliance

Although the frequency of your appliance servicing and maintenance will depend on use and the type of installation, a qualifi ed service technician should perform an appliance check-up at the beginning of each heating season.

WARNING

Risk of injury or property damage.

Before servicing:

Turn off gas.

Turn off electricity to appliance.

Ensure appliance is completely cooled.

After servicing:

Replace front and glass, if removed.

Reseal and reinstall any venting removed for servicing.

WARNING

Annual inspection by qualifi ed technician recommended.

Check:

Condition of glass, glass assembly and glass seal.

Obstructions of combustion and ventilation air.

Obstructions of termination cap.

Burner ignition and operation.

Burner air shutter adjustment

Gas connections and fi ttings.

Clean:

Glass

Air passageways, grilles, control compartment

Burner, burner ports. USE CAUTION WHEN CLEANING/

HANDLING CERAMIC BURNER.

Risk of:

• Fire

Delayed ignition or explosion

Exposure to combustion fumes

Odors

WARNING

Inspect external vent cap regularly.

Ensure no debris blocks cap.

Combustible materials blocking cap may

ignite.

• Restricted air fl ow affects burner operation.

CAUTION

Handle glass assembly with care.

NOTE: Clean glass after initial 3-4 hours operation. Longer operation without cleaning glass may cause a permanent white lm on glass.

When cleaning glass door:

Avoid striking, scratching or slamming glass.

Do NOT use abrasive cleaners.

Use a hard water deposit glass cleaner on white fi lm.

Do NOT clean glass when hot.

Turn off appliance after 3-4 hours of operation and ALLOW TO COOL.

Remove and clean glass assembly.

Replace glass assembly and operate appliance for additional

12 hours.

Refer to maintenance instructions.