LIGHTING INSTRUCTIONS
MILLIVOLT VALVE
1.STOP! Read the safety information previously listed above.
2.Turn gas control handle clockwise to the ‘OFF” position.
3.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above on this label. If you don’t smell gas, go to the next step.
4.Locate pilot (Fig. 10) – located at center of pan burner mounted on the rear of the pan burner.
5.Make sure toggle switch is in the “OFF” position (Fig. 9)
6.Turn control handle counterclockwise to the “PILOT” position (Fig. 9)
7.Place a lit match at the pilot burner, and simultaneously push in on the control handle. This should ignite the pilot. (if you have optional piezo ignitor on pilot, follow instructions below)
8.Once the pilot lights, continue to depress the control handle for one (1) minute.
9.After one minute, slowly release control handle and it will pop back out. Pilot should remain
lit. If it goes out repeat steps 1 thru 8.
•If the handle does not pop out when released, stop and immediately call your service technician or gas supplier
•If the pilot will not stay lit after several tries, turn the gas control handle to “OFF” and call your service technician or gas supplier.
•LIGHTING PILOT WITH OPTIONAL PIEZO LIGHTER
1.Follow steps 1 thru 5 above.
2.Push the control handle in and at the same time press the
3.Once the pilot lights, continue to depress the control handle for one (1) minute
4.After one minute, release control handle and the pilot should remain lit
5.If the pilot does not remain lit, rotate control handle to “OFF” position (Fig. 9)
6.Wait five (%) minutes and repeat above steps
10.Turn control handle counterclockwise to “ON”
11.Place toggle switch in the “ON” position (Fig. 9)
TO TURN OFF GAS TO APPLIANCE
Turn control handle clockwise to the “OFF” position. Do not force
PILOT ON
O
N
OFF
Pilot
Fig. 9
Millivolt
Thermopile
Fig. 10
13 | October 2006 |