8 Maintaining and Servicing the Appliance

8 Maintaining and Servicing the Appliance

Although the frequency of appliance servicing and main- tenance will depend on use and the type of installation, a qualified service technician should perform an appliance check-up annually.

Risk of injury or property damage WARNING

Risk of injury or property damage

Before servicing:

Turn off utilities to appliance.

Ensure appliance is completely cooled.

Before servicing: WARNING

Annual inspection by qualified technician recommended.

Check:

Obstructions of combustion and ventilation air.

Condition of logs.

Condition of burner assembly.

Burner ignition and operation.

Burner air shutter adjustment.

Gas connections and fittings.

Risk of:

Fire

Delayed ignition or explosion

Exposure to combustion fumes

Odors

Maintenance and Service Tasks:

Inspect

 

Maintenance Tasks

Burner Assembly

1

Remove logs and examine burner. Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution

 

 

when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be

 

 

avoided.

 

 

 

 

2

Remove any foreign objects

 

 

 

 

3

Inspect for paint condition, warpage, corrosion. Sand and repaint as necessary.

 

4

Verify unobstructed air circulation.

 

 

 

Logs

1

Inspect for broken, damaged or missing logs. Replace as necessary.

 

2

Verify correct log placement and no flame impingement causing sooting. Correct as necessary.

 

 

 

 

3

Verify logs are clean and carbon (soot) free. Logs may be cleaned with a dry bristle brush or dry cloth.

 

 

Handle logs with care as they are fragile and easily damaged.

 

 

 

Burner ignition and operation

1

Verify all gas connections are tight and leak-free.

 

2

Clean off burner top corrosion or deterioration. Replace burner if necessary.

 

 

 

 

3

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

 

 

 

4

Inspect for lifting or other flame problems.

 

5

Inspect orifice for soot, dirt or corrosion.

 

 

 

 

6

Verify manifold and inlet pressures. Adjust regulator as required.

 

 

 