5 Vent Information and Diagrams
A. Vent Table Key
The abbreviations listed in this vent table key are used in the vent diagrams.
Symbol | Description |
VMIN | Minimum Vertical Run Length 14 ft. |
VMAX | Maximum Vertical Run Length 50 ft. |
B. Horizontal Venting
Horizontal venting is NOT allowed.
C. Measuring Standards
Vertical measurements listed in the vent diagram (Figure
5.1) were made using the following standard:
• Vertical terminations are measured to top of chimney.
WARNING
Fire Hazard. Explosion Risk. Asphyxiation Risk.
Do NOT connect this gas appliance to a chimney flue serving a separate solid fuel or gas burning appliance.
•May impair safe operation of this appliance or other appliances connected to the flue.
•Vent this appliance directly outside.
•Use separate vent system for this appliance.
CAUTION
ALL vent specifications MUST be followed.
•This product is tested and listed to these specifications.
•Appliance performance will suffer if specifications are not followed.
Note: To achieve optimum performance of insert, minimize or avoid bends in exhaust vent pipe.
TERMINATION
CAP
ADAPTOR
EXHAUST COLLAR
INLET AIR COLLAR
EXHAUST
VENT PIPE
V= 14 FT. MINIMUM 50 FT. MAXIMUM
3 INCH COLLAR
(Factory installed to
stainless steel section)
WARNING: DO NOT
BLOCK PIPE END WITH
INSULATION OR ANY OTHER
SEALING MATERIAL
STAINLESS STEEL
PIPE - 3 FT. MIN.
REQUIRED (INCLUDED)
INLET AIR
VENT PIPE
COLLAR ATTACHMENT
BRACKET
Figure 5.1
10 |