A. Mantel Projections

Figure 10.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance, not the surround.

INLET AIR

12 in. MAX.

EXHAUST VENT PIPE

 

VENT PIPE

 

 

MANTEL

12 in. MIN.

MEASUREMENTS FROM

TOP EDGE OF UNIT

Figure 10.1 Clearances to Mantels or other Combustibles above Appliance

B. Installing Trim Surrounds

Combustible materials MUST NEVER overlap onto the front face.

1.Find the coiled low voltage wires and ON/OFF switch at- tached to outer right side of the insert (see Figure 10.2).

2.Reconnect the low voltage wires to the ON/OFF switch.

3.Attach surround assembly by hooking the support bracket on the locating tabs on top of the gas insert fireplace (see Figure 10.2.) Once the surround assem- bly is on the locating tabs, ensure the bottom hooks are resting on the locating pins at the base. Reposition the fireplace if necessary. Refer to surround instruc- tions provided with the decorative surround.

 

LOCATING TABS

 

FIREBOX

 

LOCATING SLOTS

Figure 10.2

Trim Surround Installation