Quadra-Fire QVI35S Listing and Code Approvals, A. Appliance Certification, B. BTU Specifications

Models: QVI35S QVI30S

1 45
Download 45 pages 60.91 Kb
Page 4
Image 4
1 Listing and Code Approvals

1 Listing and Code Approvals

A. Appliance Certification

MODELS: QVI30S, QVI35S

LABORATORY: Underwriters Laboratories, Inc. (UL)

TYPE: Vented Gas Appliance Heaters

STANDARD: ANSI Z21.88-2000CSA2.33-M00 • UL307B

This product is listed to ANSI standards for “Vented Gas Appliance Heaters” and applicable sections of “Gas Burn- ing Heating Appliances for Manufactured Homes and Recreational Vehicles”, and “Gas Fired Appliances for Use at High Altitudes”.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE. This appliance is tested and approved as either supplemen- tal room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.

Note: To assure top performance, safety and efficiency, inserts must be installed with an approved flue liner as per CAN/CGA B-149 or National Fuel Gas Code ANSI Z223 and these instructions.

Note: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.

C. High Altitude Installations

U.L. Listed gas appliances are tested and approved with- out requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada.

When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input rat- ing by changing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A., or 10% for elevations between 2000 and 4500 feet in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifice size, check with the local gas utility.

If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities.

A. Appliance Certification WARNING

Do NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

D. Non-Combustible Materials Specification

Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.

Materials that are reported as passing ASTM E 136,

Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750º C, shall be considered non-combustible materials.

B. BTU Specifications

Models

 

Maximum

Minimum

Orifice

 

Input

Input

Size

(U.S. or Canada)

BTU/h

BTU/h

(DMS)

 

 

US

32,000

22,000

#35

QVI30S (NG)

 

(0-2000 FT)

 

 

 

 

 

CANADA

28,800

19,800

#36

 

 

 

 

(2000-4500 FT)

 

 

 

 

 

 

 

 

 

 

 

 

 

US

35,500

23,500

#32

QVI35S (NG)

 

(0-2000 FT)

 

 

 

 

 

CANADA

31,950

21,150

#33

 

 

 

 

(2000-4500 FT)

 

 

 

 

 

 

 

 

 

 

 

 

 

US

31,000

18,000

#52

QVI30S (LP)

 

(0-2000 FT)

 

 

 

 

 

CANADA

27,900

16,200

#53

 

 

 

 

(2000-4500 FT)

 

 

 

 

 

 

 

US

31,000

19,000

#51

QVI35S (LP)

 

(0-2000 FT)

 

 

 

 

 

CANADA

27,900

17,100

#52

 

 

 

 

(2000-4500 FT)

 

 

 

 

 

 

 

 

 

 

 

E. Combustible Materials Specification

Materials made of or surfaced with wood, compressed paper, plant fibers, plastics, or other material that can ig- nite and burn, whether flame proofed or not, or whether plastered or unplastered shall be considered combustible materials.

F. Electrical Codes

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric

Code CSA C22.1.

A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

4

Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09

 

Page 4