4.4 Quatech Modem Control Register

The Quatech Modem Control Register can be used to set up each port. To access the QMCR write a 0xBF to the LCR (base + 3) and a 0x10 to the Options Register (base+7). This will allow the user read/write access to the QMCR. The QMCR of the entire DSCLP-200/300 is shown in Figure 9a.

Bit

Description

 

 

7 (MSB)

0 (always 0)

6

0 (always 0)

 

 

5

0 - RXEN=1

 

1 - RXEN=!TXEN

4

0 - Bits 2 and 3 are used

 

1 - RCLK=TCLK,CTS=RTS,

 

AUXOUT=AUXIN

3

0 - RCLK=TCLK,CTS=AUXIN

 

1 - RCLK=AUXIN, CTS=RTS

2

0 - AUXOUT=RTS

 

1- AUXOUT=TCLK

1-0

00 - TXEN “Auto”

 

01 - TXEN=DTR

 

10 - TXEN=RTS

 

11 - TXEN TOGGLES DURING X-MIT

Figure 9a --- Quatech Modem Control Register