7.6 Termination Resistors

Line termination resistors are provided for the input signals of each of the DSCLP-200/300's RS-422/485 ports. Termination may be selected or removed for individual signal lines using jumper blocks J6-J9.

RS-422 Rt = 100 ohm 1/2W

RS-485 Rt = 120 ohm 1/2W

RS-422/485 Receiver

 

 

+

RXD+

AUXIN+

 

Rt

 

or

 

 

-

RXD-

AUXIN-

Jumpers J6-J9

2

4

2

4

2

4

1

3

1

3

1

3

 

no termination

RS-422 termination

RS-485 termination

 

 

 

(100 ohms)

 

(120 omhs)

(factory default)

Figure 21 --- RS-422/485 Line termination resistance values

DSCLP/SSCLP-200/300 User's Manual

43

Page 43
Image 43
Quatech DSCLP-300, SSCLP-300, SSCLP-200, DSCLP-200 Termination Resistors, RS-422/485 Line termination resistance values