Quatech SSP-300, SSP-200 user manual Termination Resistors, Recommended Termination Resistor Values

Models: SSP-300 SSP-200

1 53
Download 53 pages 14.66 Kb
Page 47
Image 47
6.3 Termination Resistors

6.3 Termination Resistors

No termination resistors are provided on the SSP-200/300 ports. Both output and input signals are connected only to the external connector. Any termination which is required must be added externally.

RS-422/485 Receiver

+

RXD+

 

Rt

-

RXD-

RS-422/485 Receiver

+

-

AUXIN+

Rt

AUXIN-

Recommended Termination Resistor Values

RS-422

RS-485

100 ohm 1/2W resistor

60 ohms total resistance

 

(120 ohms at each end)

Figure 0. RS-422/485 Termination