FLAG

FLAG

DATA

CRC

FLAG

 

 

 

 

1

60–1532

2

1

Figure 1. TinyBridge-100 Frame Structure

TinyBridge-100 WAN interface operates in DTE mode. This means it accepts receive and transmit clocks. The timing diagram is shown in Figure 2.

Rx Data

Rx Clock

tSETUP tHOLD

5ns 5ns

Tx Data

Tx Clock

tDELAY

9ns

Figure 2. Receive and Transmit Clock

Timing Diagrams

APPLICATIONS

Figure 3. Bridging and Extending Ethernet over Baseband Modems

Figure 4. Bridging Ethernet over Multiplexed E1/T1 Links

Page 3
Image 3
RAD Data comm specifications Applications, 5ns 5ns, Flag, Data, TinyBridge-100 Frame Structure