AMC-101Installation & Operation Manual

Chapter 3 - Operation

 

 

 

 

 

 

 

 

 

Grounding

Note

3.2 Cable Connections

DC adapter Connection.

In order to protect the AMC-1 from electrostatic discharge (ESD), use a DC adapter where the (-) DC pole is connected to the protective earth.

3.3 Dry Contact Circuit and Connector for Alarms

A dry circuit with a 9-pin D-type connector on the rear panel, has been added to the unit to signal minor and major alarms. The dry contact circuit is used to signal the following alarms:

Alarm type

Description

 

 

RED ALARM

Power Failure (DC voltage on board)

 

 

YELLOW ALARM

Signal Detect Failure (to any of the unit modules)

 

 

CONFIG ALARM

Improper Configuration (incompatible modules

 

and/or data rates selected)

 

 

Three pins are dedicated for each alarm: Common (COM), OK and FAIL. The COM pin is the input for each alarm. The user can drive the COM pin with any signal (0 to 5v). If the signal is received OK, the COM pin is connected to its corresponding OK pin; If there is a failure, the COM pin is connected to its corresponding FAIL pin. See Table 3-4and Figure 3-3for the connector pin assignments.

Table 3-4 Connector Pin Assignment

Alarm Type

 

 

 

 

COM

OK

 

FAIL

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

9

 

4

5

 

 

 

 

 

 

 

 

 

 

 

 

 

YELLOW

3

 

8

7

 

 

 

 

 

 

 

 

 

 

 

 

 

CONFIG

6

 

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 3-3 Connector Pin Assignment

Dry Contact Circuit and Connector for Alarms

3-3

Page 62
Image 62