Rangemaster E6448SS, E64000 Horizontal Discharge Installation Internal Blowers Only, 1 2

Models: E6448SS E64000

1 48
Download 48 pages 34.34 Kb
Page 9
Image 9
6.CHOOSE THE OPENING(S) (INTERNAL BLOWER HOODS ONLY)

6.CHOOSE THE OPENING(S) (INTERNAL BLOWER HOODS ONLY)

Remove the knockout for the chosen opening(s) (horizontal at the back of the hood or vertical on top). See illustrations below.

VERTICAL DISCHARGE

HORIZONTAL DISCHARGE

NOTE: For ducted installation only.

1 1  2  3 2 7. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) ONLY) 3

1 Manual background 2 Manual background 3

HR0021

Punch out the appropriate electrical knockout hole on top (A) or back (B) of the hood. Install the wire clamp (included in parts bag).

NOTE: For a non-ducted installation, punch out the back electrical knock-out (B).

A

B

HR0024

 

7. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) ONLY)

All internal blower hoods are factory shipped with the blowers mounted for a vertical discharge configuration. For a horizontal discharge configuration, disassemble the blower(s) from the inner top of the hood and mount it (them) to the back panel of the hood. The procedure below applies for one or two motors.

Unplug the blower.

Using a 5/16” socket, remove all blower mounting screws from the inner top of the hood. Keep the screws for further use.

HE0085

LEFT SIDE MOUNTING

SCREW LOCATION

HD0269

RIGHT SIDE

MOUNTING SCREW

LOCATION

HD0282