Rangemaster U106140-05 Technical Data, This cooker is designed for use on either, Dimensions

Models: U106140-05

1 36
Download 36 pages 24.7 Kb
Page 35
Image 35
Technical Data

Technical Data

This cooker is designed for use on either :-

NATURAL GAS (Cat I2H ) at 20mbar or LP GAS (Cat I3+ ) Butane 29mbar / Propane 37mbar.

NB: THE NATURAL GAS AND LP GAS VERSIONS OF THESE COOKERS ARE DIFFERENT MODELS AND CANNOT BE CONVERTED FROM ONE GAS FAMILY TO THE OTHER

INSTALLER: Please leave these instructions with the User.

DATA BADGE LOCATION : LOWER RIGHT HAND COOKER UPRIGHT (Remove storage drawer)

Country of Destination: GB/IE

Gas

 

Electric

Natural Gas

20mbar

220 - 240V 50Hz

Butane

29mbar

 

Propane

37mbar

 

(See appliance data badge for test pressures)

Dimensions

Overall height

minimum 893mm

maximum 920mm

Overall width

1100mm See ‘Positioning of Cooker’

Overall depth

648mm

 

Space for fixing

See ‘Positioning of Cooker’

Minimum space above hotplate

650mm

 

Connections

Gas:

Electric

Rp 1/2 at rear right-hand side

220 - 240V 50Hz

Ratings

 

Natural Gas

 

L.P. Gas

 

 

 

 

 

 

Hotplate

 

Injector

 

Injector

Right hand High burner

3.0kW

128

3.0kW (210g/h)

87

Large Burner

3.0kW

134

3.0kW (210g/h)

87

Medium Burners

1.7kW

109

1.7kW (119g/h)

68

Small Burner

1.0kW

75

1.0kW (70g/h)

51

Ovens

3.2kW

237

2.9kW (224g/h)

85

Grill

2.73kW

190

2.73kW (192g/h)

85

Gas burner inputs based on Gross Calorific Value

Warmer

160W

35

Page 35