Raymarine ST40 manual Stand-alone connections

Models: ST40

1 45
Download 45 pages 51.08 Kb
Page 27
Image 27

18

ST40 Compass Instrument Owner’s Handbook

Stand-alone connections

CAUTION

Ensure that the power supply for each stand-alone ST40 instrument is protected by a 3 A fuse or circuit breaker.

3 A circuit breaker

Red +ve

Uninsulated wire (screen) -ve

Power cable

Note:

A 3 A fuse can be used in place of the circuit breaker, if preferred.

12 V dc supply

_

+

(e.g.battery)

 

 

Red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screen

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yellow

 

 

 

 

 

 

 

 

Cable from

 

 

 

 

 

 

Blue

 

 

 

 

 

 

 

 

Fluxgate Compass

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

transducer

Connections to a stand-alone instrument

 

 

 

 

 

 

 

D4779-2