SECTION I: ELECTRICAL POWER CONNECTIONS

SECTION I: ELECTRICAL POWER CONNECTIONS

Installations must follow these codes:

·National Electrical Code and any other national, state, provincial or local codes or regulations having jurisdiction

·Safety wiring must be N.E.C. Class 1

·Heater must be electrically grounded as required by N.E.C.

·In Canada, C22. 1

The heater is wired for 120 Volts, 12 AMPS. The voltage is indicated on the tie-in leads. Consult the wiring diagram shipped with the heater in the instruction packet. The remote tank control stat, thermostat, or electronic heater control as applicable, may be connected to stage selector terminal (See wiring diagram). 24 Volts are supplied to this connection through the heater transformer. DO NOT attach line voltage to the “TH” leads. Before starting the heater check to insure proper voltage to the heater and pump.

Install a separate disconnect means for each load. Use appropriate-sized wire as defined by NEC, CSA and/or local code. All primary wiring should be 125% of minimum rating.

It is strongly recommended that all individually-powered control modules and the heater should be supplied from the same power source.

SURGE PROTECTION

Microprocessor-based and solid state controls are vulnerable to damage from voltage and amperage fluctuations in the power supply. All sensitive control components should be protected by a suitable commercial-grade surge protection device.

If any of the original wire as supplied with the heater must be replaced, it must be replaced with 105°C wire or its equivalent.

CHECK THE POWER SOURCE

Using a volt-ohm meter (VOM), check the following voltages at the circuit breaker panel prior to connecting any equipment: Make sure proper polarity is followed and house ground is proven.

FIGURE I-1

CHECK POWER SOURCE

BLACK CIRCUIT

BREAKER

WHITE

GREEN

GROUND

A B C

AC = 108 Volts AC Minimum, 132 VoltsAC MAX AB = 108 Volts AC Minimum, 132 VoltsAC MAX BC = < 1 VoltAC

VOLT-OHM

METER

Fig. # 9237