VENTING CONNECTIONS (Indoor Models)

VENTING CONNECTIONS (Indoor Models)

The drafthood is shipped separately and must be installed on the heater.

For Model 260/261:

1.Mount drafthood on top of heater and attach with the 4 sheet metal screws provided. Drafthood should be positioned with the vent sensor located on the front left side as shown.

2.Remove plastic plug from left side of heater jacket and install plastic grommet provided.

3.Route flue sensor wire harness through the grommet installed in Step 2.

Fig. #9351

4. Remove door and locate wire from roll out sensor to Hi Limit with the male/female connector.

WIRE FROM TRANSFORMER

MALE/FEMALE

WIRE TERMINAL

WIRE FROM HIGH LIMIT

ROLL OUT SENSOR

WIRE FROM TRANSFORMER

CONNECT ONE VENT SENSOR WIRE TO HIGH LIMIT WIRE

CONNECT ONE VENT SENSOR WIRE TO ROLL OUT SENSOR WIRE

ROLL OUT SENSOR

Before Installation of Draft Hood

After Installation of Draft Hood

 

Fig. #8947.2

Fig. #8947.3

5. Disconnect male/female connector and attach to the 2 wires from drafthood vent sensor harness.