ELECTRICAL (STANDING PILOT)

ELECTRICALTROUBLESHOOTING

For Service Technicians

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STARTHEATER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IF PILOT BURNER LIGHTS

 

 

 

 

 

 

 

 

 

BUT MAIN BURNERS DO NOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHECK FOR 24 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AT GAS VALVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IF NOT 24 V:

 

 

 

 

 

 

IF 24 V:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHECK TRANSFORMER OUPUT

 

REPLACE

 

FOR 24 V

 

GAS VALVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IF PILOT BURNER

DOES NOT LIGHT

CHECKTHERMOCOUPLE

 

 

 

 

 

 

 

IF O.K.

 

 

IF DEFECTIVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REPLACE

 

REPLACE

GAS VALVE

 

THERMOCOUPLE

 

 

 

 

 

 

 

IF NO 24V:

REPLACE TRANSFORMER

IF 24 V:

PROBLEM IN

LIMIT

CIRCUITS

WARNING

HIGH VOLTAGE

For Qualified Technicians ONLY

29