TROUBLESHOOTING GUIDE

 

Problem

Possible Cause

Solution

 

 

 

 

 

 

 

AquaViéwater

The mineral dispenser

Replace the mineral dispenser.

 

 

has an unusual taste. is contaminated.

See page 3.

 

 

 

The water bottle is in

Clean the water bottle.

 

 

 

need of cleaning.

See page 3.

 

 

 

The boiling chamber

Do not overfill the boiling

 

 

 

has been over-filled.

chamber. Fill to bottom of

 

 

 

 

the four tabs at the base of

 

 

 

 

the boiling chamber’s fill

 

 

 

 

opening. See #4 on page 4.

 

 

AquaViéunit

The boiling chamber is not

Push the boiling chamber into

 

 

is leaking.

properly installed.

the AquaViéchassis so that

 

 

 

 

both the boiling chamber and

 

 

 

 

the electrical connection are

 

 

 

 

tightly joined. See page 5.

 

 

 

The o-ring is damaged or

If damaged, replace o-ring.

 

 

 

missing from the baffle.

Make sure the o-ring is

 

 

 

 

properly placed on the baffle,

 

 

 

 

fitting in the circular groove.

 

 

 

 

See page 5.

 

 

 

The flat gasket between

Replace gasket.

 

 

 

the boiling chamber

 

 

 

 

spout and baffle is

 

 

 

 

missing or damaged.

 

 

 

 

 

 

 