13)Replace Burner Tray and reverse steps 6) to 1).

INSTALLATION

11)Remove and discard the 3 pressure regulator mounting screws (A), pressure regulator tower (B) and diaphragm (C).

12)Insure that the rubber gasket (D) is properly positioned and install the new HI/LO pressure regulator assembly to the valve using the new screws (E) supplied with the kit. Tighten screws securely.

13)Replace Burner Tray and reverse steps 6) to 1).

14)Adjust the burner aeration setting from 1/8" to 3/16" as required for the best fl ame picture.

15)Remove the switch cover from the left side of the body base and pull the thermodisc out of the bracket under the left side of the fi rebox bottom and replace with the Thermodisc supplied with this kit.

16)Attach clear label "This unit has been converted to Propane" near or on the serial # decal.Attach white label "This valve has been converted from NG to LPG using SIT conversion Kit Code 0.907.202" onto the valve.

Remove the 2 nuts holding the switch box in place, then pull the thermosdisc out of the bracket.

17) Replace yellow

18) Check for gas leaks.

19) Check inlet and outlet pressures.

20) Check operation of fl ame control.

21) Check for proper fl ame appearance and glow on logs.