Remove Left & Right Side Base

MAINTENANCE

8)Remove the Side Base Brick Panels and finally the Long Base Brick Panels.

Remove Left & Right Side Base

Brick Panels

Remove the 2 Long Base Brick Panels

9)Disconnect the inlet gas line.

10)Disconnect the 2 TP wires and the 2 TH wires from the valve.

11)Remove the 16 Phillips head screws secur- ing the valve tray.

12) Lift the entire assembly out.

13)Undo the pilot tube from the valve with a 7/16" spanner.

14)Undo the quick drop out thermocouple nut on the valve with a 9mm (metric) spanner.

15)Remove the Piezo igniter wire and push button assembly.

16)Undo the "gas out" flare nut with a 13/16" spanner.

17)Undo the "gas out" flare fitting with an 11/16" spanner.

18)Remove the 6 Phillips head screws from the sides of the valve bracket and remove valve.

Hint: If you are using black pipe, ensure that there is a union by the valve, otherwise removal will be almost impossible.

INSTALLING VALVE

1)Attach the valve to the valve bracket with the 6 (m5x8 metric) screws provided.

2)Reconnect the "gas out" flare fitting with an 11/16" spanner.

3)Reconnect the "gas out" flare nut with a 13/ 16" spanner.

4)Install piezo ignitor push button assembly and reconnect wire.

5)Reconnect the quick drop out thermocouple nut with a 9mm spanner.

6)Reconnect the pilot tube nut with a 7/16" spanner.

7) Scrape off the old gasket from the floor of the firebox and from the valve tray assem- bly.

8)Install a new gasket and reinstall the valve tray assembly.

Note: Failure to install a new gasket may severely affect the appliance perform- ance.

9)Reinstall the 16 hold down screws.

10)Hook up the 2 TP and 2 TH wires to the appropriate connections on the valve.

11)Reinstall the Burner Assembly.

13)Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector. (Do not use open flame for leak testing.)

14)Fire up the unit temporarily

15)Check the manifold pressure.

16)Reinstall the logs, grate and brick panels as needed.

17)Reinstall the glass doors.

18)Fire up the unit again and check for proper flame appearance.

32

Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace