FAN MAINTENANCE

MAINTENANCE

FAN MAINTENANCE

4) Lift fan off of the 2 pins, tip back and pull

 

 

through the opening. Disconnect the green

If your fan requires maintenance or replace-

ground wire from the right side of the fan

as soon as you can reach it.

ment, access to the fan is through the plate on

 

the rear wall of the firebox. NOTE: the unit

 

MUST NOT be operated without the fan

 

access panel securely in place and cor-

 

rectly sealed.

 

IMPORTANT:These fans collect a lot of dust from within your home. En- sure you maintain these fan motors on a regular basis by vacuuming out the fan squirrel cages, around the motor, and around the grills on the back of the stove.

IMPORTANT

Disconnect power supply

before servicing

REMOVING VALVE

If your valve requires maintenance or replace- ment, use the following instructions:

Note: Always close off the gas supply

before removing the valve.

1)Open front pedestal door. You may want to put a soft cloth on the base of the unit so that when the pedestal door is open it doesn't scratch the paint. See diagram below.

WARNING:

Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

To remove fan:

1)Unplug or disconnect power source to stove.

2)Remove the rear Disconnect power supply access panel on

the back of the stove. The fan can only be ac- cessed from the back of the stove.

3) Unclip the black and white wires from the fan mo- tor.

Replacing Fan:

Reverse the above steps (1 - 4). Make sure the fan wires and the ground wire are reattached.

Hint for pushing fan down onto pins - rub a bit of dish soap on the grommet so it will slide more easily onto the pin. Check to make sure the fan is seated properly on the pins - try to move the fan back and forth, there should be no noise, if there is check that the grom- mets haven't come loose.

2)Undo the six screws holding the control panel in place.

3)Disconnect all wires from the back of the control panel and then remove panel. You should lay the panel on a soft cloth so it doesn't get marked up. See diagram above.