Regency U37-LP PROPANE, U37-NG NATURAL GAS Safety Label, Door Seal Adjustment, 918-028a

Models: U37-NG NATURAL GAS U37-LP PROPANE

1 32
Download 32 pages 57.44 Kb
Page 4
Image 4
SAFETY LABEL

SAFETY LABEL

This is a copy of the label that accompanies each ULTIMATE Rear Vent Direct Vent Free- standing Gas Stove. We have printed a copy of

the contents here for your review. The safety label is located on the inside of the drop down pedestal door.

NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

Copy of Safety Label for U37

Listed: GRAVITY DIRECT VENT WALL FURNACE

Certified for/Certifiée pour: CANADA AND U.S.A.

Tested to: CGA 2-17-M91, ANSI Z21.88b-2003/CSA 2.33b-2003 REPORT NO. 476-1846-00 (Oct. 2000)

MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE

Serial No./No de serie

221

DO NOT REMOVE THIS LABEL /

NE PAS ENLEVER CETTE ÉTIQUETTE

 

 

 

FACTORY EQUIPPED FOR NATURAL GAS: Model U37-NG ÉQUIPÉ À L'UISINE POUR GAZ NATURAL:

 

 

 

 

U37-NG

Model/Modele:

Min. supply pressure

5.0"

WC/C.E. (1.24Kpa)

Pression d’alimentation minimum

 

 

Manifold

pressure

High 3.8"

WC/C.E. (0.947Kpa) Pression à la tubulure d’échappement élevée

 

Manifold

pressure

Low 1.1"

WC/C.E. (0.27Kpa)

Pression à la tubulure d’échappement élevée

 

 

 

 

 

 

Orifice size

 

#37

DMS

 

Dimensions de l’orifice

 

 

 

 

 

 

 

 

Altitude

 

 

0-4500

ft/pi

(0-1370m)

L’altitude

 

 

 

 

 

 

 

 

Maximum

Input

 

30,000

Btu/h

(8.79Kw/h) Débit calorifique maximum selon

 

 

 

Minimum

Input

 

15,000

Btu/h

(4.39Kw/h) Débit calorifique minimum selon

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FACTORY EQUIPPED FOR PROPANE: Model U37-LP

ÉQUIPÉ À L'UISINE POUR GAZ PROPANE:

 

 

 

Min. supply pressure

12"

WC/C.E. (3.00Kpa)

Pression d’alimentation minimum

 

 

 

 

U37-LP

Model/Modele:

Manifold

pressure

High 11"

WC/C.E. (2.74Kpa)

Pression à la tubulure d’échappement élevée

 

 

Manifold

pressure

Low 2.9"

WC/C.E. (0.72Kpa)

Pression à la tubulure d’échappement élevée

 

 

 

 

 

 

Orifice size

 

#52

DMS

 

Dimensions de l’orifice

 

 

 

Altitude

 

 

0-4500

ft/pi

(0-1370m)

L’altitude

 

 

 

 

 

 

 

 

Maximum

Input

 

30,000

Btu/h

(8.79Kw/h) Débit calorifique maximum selon

 

 

 

 

 

 

 

 

 

 

 

Minimum

Input

 

15,000

Btu/h

(4.39Kw/h) Débit calorifique minimum selon

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VENTING: Only for direct discharge without duct connection. This appliance must be installed in accordance with the manufacturer's installation instructions and with local codes, if any; if not, follow the current ANSI Z223.1 in the USA or the current CAN/CGA-B149 in Canada. For Manufactured Home Installation: This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.

Electrical supply 115VAC, 1.13 A, 60 Hz. Not for use with solid fuel.

FPI Fireplace Products International Ltd., Delta, BC, Canada MADE IN CANADA / FABRIQUE AU CANADA

 

DOOR SEAL ADJUSTMENT:

 

 

Please check that door is properly sealed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Periodic adjustment of latch may be required.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

918-028a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum

Clearances to Combustibles/ Degagement Minimum Des Materiaux Combustibles

A7-1/2" /190 m m B3" /76 m m E 4-1/2" /114 m m

Min. Ceiling

Height from top

of unit / Min.

Plafond Hauteur

en haut de l'appareil:

36" / 914 mm

For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.

For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appli- ances individual manual shut-off must be a t-handle type valve.