INSTALLATION

INSTALLATION

CLEARANCES TO

CHECKLIST

COMBUSTIBLES

LOCATING YOUR

ULTIMATE GAS STOVE

1)Check Clearances to Combustibles (page 6), location of unit (page 6) and venting requirements (pages 6-10).

2)Install venting: Check all venting require- ments, pages 8-14.

3)Make gas connections, page 17. Test the pilot. Must be as per diagram, pages 17 & 24.

4)If necessary, convert from Natural Gas to Propane (page 16).

5)Install log set, page 17.

6)Install Front Door Front, page 19.

7)Test Gas Pressure, page 19.

8)Install Louvers, page 20.

9)Install optional Remote Control, or Wall Ther- mostat, page 20.

10)Final check, page 20.

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to customer.

This includes:

1)Clocking the appliance to ensure the cor- rect firing rate (rate noted on label) after burning appliance for 15 minutes.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibil- ity of the manufacturer.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

The clearances listed are MINIMUM distances. Measure the clearance to both the appliance and the chimney connector. The farthest distance is correct if the two clearances do not coincide. For example, if the appliance is set as indicated in one of the diagrams but the connector is too close, move the stove until the correct clearance to the connector is obtained.

This appliance may be installed only with the clearances as shown in the situations pictured.

Do not combine clearances from one type of installation with another in order to achieve closer clearances.

This unit can be installed on a solid combustible surface like a wood floor. This unit can also be installed directly on carpeting or vinyl when the bottom pedestal cover plate (provided with unit ) is installed.

Use the minimum clearances shown in the diagrams below:

U37-NG & U37-LP Clearances

A Side Wall to Unit

7-1/2" / 190 mm

B Back Wall to Unit

3" / 76 mm

E Side Wall to Unit

4-1/2" / 114 mm

U37-NG & U37-LP

Reference Dimensions

C Floor to Flue Centerline

25" / 635 mm

D Side Wall to Flue Centerline 20-1/2" / 521 mm

When selecting a location for your stove, en- sure that the clearances listed above are met as well as ensuring that there is adequate acces- sibility for servicing and proper operation.

For Vent Termination requirements, see page 7.

This appliance is Listed for bedroom installa- tions when used with a Listed Millivolt Thermo- stat. Some areas may have further require- ments, check local codes before installation.

This appliance is Listed for Alcove installations, maintain minimum Alcove clearances as fol- lows, minimum ceiling height of 66"(1.7m), minimum width of 41"(1.0m) and a maximum depth of 36"(0.9m).

A)Cross Corner

B)Flush with Wall/Alcove

C)Flat on Wall Corner

D)Flat on Wall

COMBUSTION AND VENTILATION AIR

The combustion air from this appliance is drawn from outside the building through the outer flue.

Extra provision for combustion air inside the room is not required.

VENTING

The Regency Direct Vent System (Horizontal Termination Kit (640-944) and the Vertical Ter- mination with the Co-linear Flex System in combination with the ULTIMATE Direct Vent- Rear Freestanding Gas Stoves (U37-NG and

1) Ensure that structural members are not cut

Minimumceilingheight

or weakened during installation.

is 36" / 914 mm from

 

top of unit.

2)Ensure proper grounding using the #8 ground lug provided.

3)Appliance must be anchored to the floor with the supplied anchoring methods.

U37-LP) have been tested and listed as direct vent heater systems by Warnock Hersey.

The Horiz. Termination Kit (640-944) includes everything required for a straight through the wall installation, or add a 45o elbow for a corner installation. If a snorkel termination is required, the Simpson Dura-Vent Direct Vent System Model DVGS terminals are available.

6

U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater

Page 6
Image 6
Regency U37-LP PROPANE, U37-NG NATURAL GAS Clearances to, Checklist Combustibles Locating Your Ultimate GAS Stove, Venting