Regency Wraps F2400M, S2400M Installation, Minimum Alcove Clearance to Combustible Materials

Models: F2400M S2400M

1 28
Download 28 pages 12.91 Kb
Page 9
Image 9
Minimum Alcove Clearance to Combustible Materials

INSTALLATION

Minimum Alcove Clearance to Combustible Materials

The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level.

Note: Minimum alcove ceiling height - 84"

Maximum depth of alcove - 36"

 

 

 

 

From

From Flue

Min.

Min.Hearth

 

 

 

Unit

 

Unit

Center-line

Width

to Rear Wall

 

 

 

 

G

H

I

J

K

L

 

 

Medium F2400M

with Airmate

15" (381 mm)

5.5" (139 mm)

27" (685 mm)

12" (304 mm)

54" (1371 mm)

48" (1219 mm)

 

 

 

with Rear Deflector

15" (381 mm)

6.5" (165 mm)

27" (685 mm)

13" (330 mm)

54" (1371 mm)

49" (1244 mm)

 

 

 

 

 

 

 

 

 

 

 

Medium S2400M Step Stove

15" (381 mm)

5.5" (139 mm)

27" (685 mm)

12" (304 mm)

54" (1371 mm)

48" (1219 mm)

 

 

 

 

 

 

 

 

 

 

 

Floor Protection

A combustible fl oor must be protected by non-combustible material (like tile, concrete board, or certifi ed to UL-1618 or as defi ned by local codes) extending beneath the heater and a minimum of 6" (152mm) from each side and minimum 16" (406mm) from the front face of the stove and minimum 6" (or the rear clearance to combustibles whichever is smaller) from the rear of the stove.

When installed with horizontal venting, non-combustible floor protection must beneath the fl ue pipe and extend 2" (51mm) beyond each side.

Minimum Overall Width (X) of Floor

Protector for all installations:

Stove

F2400M

36" (914 mm)

 

 

 

 

 

 

 

 

 

 

Step Stove

S2400M

36" (914 mm)

 

NOTE: In Canada, floor protection must extend 18" (450mm) to the

 

 

 

 

 

 

 

 

front and 8" (200mm) to each side and back of the stove.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Overall Depth (Y) of Floor Protector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Residential

 

Residential

Mobile Home

 

Alcove

 

 

Unit

 

 

"C" Vent

 

Close Clearance

Close Clearance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

Z

 

Y

 

Z

Y

 

Z

Y

Z

Medium F2400M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

with Airmate

 

46" (1168 mm)

6" (152 mm)

45"* (1143 mm)

5" (127 mm)

45" (1143 mm)

5" (127 mm)

45"* (1143)

5" (127 mm)

with Rear Deflector

46" (1168 mm)

6" (152 mm)

45" (1143 mm)

5" (127 mm)

45" (1143 mm)

5" (127 mm)

45" (1143)

5" (127 mm)

 

 

 

 

 

 

 

 

 

 

 

 

Medium S2400M

 

46" (1168 mm)

6" (152 mm)

45"* (1143 mm)

5" (127 mm)

45" (1143 mm)

5" (127 mm)

45"* (1143)

5" (127 mm)

- Step Stove

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*The rear clearance to combustibles is less than 6" (, for corner installations the rear corners may be angled to take advantage of the closer clear- ances.