SAFETY LABEL
This is a copy of the label that accompanies each Regency ULTIMATE Gas Insert. We have printed a copy of the contents here for your review. The safety label is located on the right side door panel.
NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli- ances individual manual
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.
Duplicate
Serial No. 225
DO NOT REMOVE THIS LABEL
Serial No. 225
Listed: Vented Gas Fireplace Heater
Certified: For Canada & USA
Tested to: CAN/CGA
ANSI
NATURAL GAS FIREPLACE INSERT
Model
Altitude
Min. Supply Pressure | 5" | WC/C.E. (1.25kPa) | |
Manifold Pressure High 3.8" | WC/C.E. (0.94kPa) | ||
Manifold Pressure Low | 1.1" | WC/C.E. (0.27kPa) | |
Orifice Size | #32 | DMS |
|
Altitude | ft/pi | ||
Maximum Input | 38,000 Btu/h | (11.14Kwh) | |
Minimum Input | 20,000 Btuh | (5.86Kwh) | |
NATURAL GAS FIREPLACE INSERT | |||
Model |
| ||
Field Convertible for Altitude | |||
(Report No. |
| ||
Min. Supply Pressure | 5" | WC/C.E. (1.25kPa) | |
Manifold Pressure High | 3.8“ | WC/C.E. (0.94kPa) | |
Manifold Pressure Low | 1.1" | WC/C.E. (0.27kPa) | |
Orifice Size | #33 | DMS |
|
Altitude | |||
Maximum Input | 34,000 Btu/h | (9.96Kwh) | |
Minimum Input | 18,000 | Btu/h | (5.28kwh) |
|
| ||
PROPANE GAS |
| ||
Model |
| ||
Min. Supply Pressure | 12" | WC/C.E. (3.00kPa) | |
Manifold Pressure High | 11" | WC/C.E. (2.74kPa) | |
Manifold Pressure Low | 2.9" | WC/C.E. (0.72kPa) | |
Orifice Size | #50 | DMS |
|
Altitude | ft/pi | ||
Maximum Input | 38,000 | Btu/h | (11.14Kwh) |
Minimum Input | 20,000 | Btu/h | (5.86Kwh) |
|
|
|
|
|
|
|
|
This appliance must be installed in accordance with local codes, if any; if not, follow current ANSI Z223.1 /
direct discharge without duct connections. NOT
FOR USE WITH SOLID FUEL. Electrical Supply 115V,1.13A, 60Hz. WARNING: This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or
solid fuels unless all original parts have been replaced
and the fireplace
having jurisdiction.
MINIMUM CLEARANCES TO
COMBUSTIBLES: FROM HEATER
Side Wall: | A | 7.5" | (190mm) |
Ceiling: | B | 35" | (890mm) |
Mantel: | C | 11" | (280mm) |
Mantel Width: | G | 5.5" | (140mm) |
Alcove Width: | K | 48" | (1120mm) |
Max.Alcove Depth | M | 36" | (915mm) |
|
| B |
|
| G |
|
|
C |
| L | H |
|
|
| |
A |
| J |
|
|
| K |
|
M |
|
|
|
| |||
Hearth Height | Hearth Depth |
(H)(L)
Option #1: | 4.0" (100mm) | 16" (405mm) |
Option #2: | 0.5" (15mm) | 24" (610mm) |
Hearth Width | (J) 40"(1015mm) | |
| ||
FPI Fireplace Products International Ltd. | ||
| Delta, B.C. |
|
Made in CANADA |
4 | Regency |