INSTALLATION
support as well as the floor beneath the hearth extension.
Note: The “Z” type safety strip is not supplied by Regency and must be fabricated locally.
In Canada:
Any factory built chimney listed and certified to
1)GSW Heating Products Model JFC
2)Oliver McLeod Ltd. Model
3)Security Chimney Ltd. Model ASHT
4)Selkirk Metalbestos Model SS
5)ICC Excel 103 HT
6)ICC Excel 2100
In U.S.A.
Any of the following chimney systems covered by
1)American Metal Product
2)GSW Heating Products Model FC
3)Oliver McLeod Ltd. Model
4)Security Chimney Ltd. Model ASHT
5)Security Chimney Ltd. Model S2100
6)Security Chimney Ltd. Model Sentinel
7)Selkirk Metalbestos Model SS II
8)Simpson
9)ICC Excel 103 HT
10)ICC Excel 2100
Chimney Height
The total height of your WarmHearth fireplace system from the surface the fireplace rests on to the chimney top must not exceed 36 ft. and must also meet minimum system height chart. Please refer to the Flue Manufacturer's Instruc- tions for specific details. Refer to Page 12 for Minimum Flue System Heights.
Chase Enclosure
A chase is a vertical
A chase should be constructed just like any outside wall. In a cold climate, we recommend the base of the chase be insulated between the solid continuous floor beneath the fireplace and the chase bottom. If used, the value and amount of chase insulation in a cold climate installation is optional and not required for safety. Insulation is recommended to avoid
2)Refer to fireplace drawing and specifica- tions on page 6 and page 7 for framing dimensions and details. framing header may be positioned directly on top of the front fireplace
IMPORTANT:Undernocircumstanc- es can the fireplace top or side spacers be removed or modified. Do not notch the header to be in- stalled closer than the fireplace out- side facing spacers.
3)Fireplace must be anchored to the framing to prevent movement or rocking; use wall grips or seismic brackets which have been supplied. These angle brackets are installed by attaching them to the side of the unit and to the back side of the 2 x 4 or further back on 2 x 6 framing.
CHIMNEY SYSTEM CONSIDERATIONS
Regency’s WarmHearth Fireplace is to be in- stalled with one of the following Chimney Sys- tems only. Chimney systems going from 7 in. to 8 in. diameter (with adaptor
Note: Anchor Plate/Fireplace Adaptor must be purchased with Chimney sys- tem.
The use of only one of these systems is permitted when installing the WarmHearth. Do not alter or mix parts from other systems as this may cause a potential hazard and void Regen- cy’s limited warranty.
Ventilated Chase Pan
heat loss.
Note: Insulation does not come in contact with Chimney. Maintain a 2 in. clearance.
Regency Z2510 WarmHearth | 9 |