Regency Wraps Z2510L Installation, Masonry Liner Bricks, Louvers, Door Handle, Latch Adjustment

Models: Z2510L

1 24
Download 24 pages 61.62 Kb
Page 19
Image 19
MASONRY LINER/

INSTALLATION

MASONRY LINER/

BRICKS

Insulated refractory panels are included to extend the life of the fireplace and help radiate heat more evenly. Make sure Insulating Paper is in place along the bottom, side and rear before bricks are put into place. Insulation batt, 1 in. thick is placed above the top brick baffle.

Using the diagram to find the correct location of the panels install in the following sequence: sides, rear, bottom, top. Care should be taken not to damage the panels during installation.

THE LOG ANDIRONS SHOULD NOT BE RE- MOVED.

LOUVERS

DOOR HANDLE

The unit comes with a standard black door or optional gold plated door. After the unit has been installed and the facing completed place the door onto the door hinges. Put hinge cover caps on top of hinge to complete the door. Install the gold spring handle onto the handle bar.

fit in order to prevent it from falling out when a fire is burning.

OPERATING

INSTRUCTIONS

Draft Control

Both the primary and air wash drafts are controlled by the control rod located under your ash lip. To increase your draft, push left for open, to decrease push right for closed. The draft control box is removable should it require attention. From time to time a high temp lubricant may be needed to keep the draft control sliding easily. It must, however, be re-sealed with RTV, high temperature silicone, when replaced.

The unit comes with standard black louvers but can have Gold Plated Louvers as an option. There are 2 sets of louvers: the top consists of 4 louvers and the bottom has 5 louvers.

To attach the louvers first slide 2 spring nuts into place making sure the smaller holes are on the back of the unit. Louvers are held in place by feeding the two screws through the spring nuts. Louvers can be removed by inserting a screw driver between the louvers and remov- ing the screws.

LATCH ADJUSTMENT

The door latch may require adjustment as the door gasket material compresses after a few fires. Removal of the spacer washer shown in the diagram below will allow the latch to be moved closer to the door frame, causing a tighter seal. Remove and replace the nuts, washer and spacer as shown.

GLASS INSTALLATION

Remove the wire retainer from the door, and place the glass in the door, making sure that the glass gasketing will properly seal your unit. The retainer should be resting on the gasketing not on the glass. Tighten securely, but do not wrench down on the glass as this may cause breakage. Do not substitute materials. If your glass door breaks, do not use your unit until it has been replaced. See glass replacement section on page 19.

SECONDARY AIR TUBE

INSTALLATION

1)Slide air tube into the hole on the left hand side of the firebox as far as it will go. The notch in the air tube should be facing the right hand side of the firebox.

2)Slide the air tube back towards the right side until it locks into place. To lock into position, use a pair of vise grips and tap them with a mallet until the tube locks into place. The air holes should be pointing down toward the primary air opening just inside the bottom of the door opening. The air tube will be difficult to snap into place because it has to be a snug

FIRST FIRE

When your installation is completed and in- spected you are ready for your first fire.

1)Open draft control fully. To the left is open, to the right is closed.

2)Open firebox door and build a small fire using paper and dry kindling. Secure door on the firebox and wait a few minutes for a good updraft in the flue to establish the fire. Leaving the door slightly open will help your fire start more rapidly and keep glass clean. Add more kindling; then 2 x 2 or 2 x 4 softwood to establish a hot coal bed before adding larger cordwood.

Regency Z2510 WarmHearth