How to operate your fixture

How to operate your fixture

Step 1: Move slide switch on bottom of the sensor to TEST. There are three sensitivity settings: L (low), M (medium) and H (high). Low will be the least sensitive and high will be the most sensitive. Approximate detection ranges are as follows:

L . . . . . . 30 feet (short range) M . . . . . 40-50 feet (mid-range)

H. . . . . . 60 or more feet (maximum range)

NOTE: Temperature can affect the sensitivity of the motion sensor.

 

 

It may be necessary to readjust the sensitivity when there are

1

SENSITIVITY

major temperature changes. Set sensitivity slide switch to

2

medium or “M”.See diagram (O).

3

H

4

Step 2: Turn on the power to fixture. Allow fixture to warm up approx-

M

TEST

L

imately two minutes before testing. (Lights may or may not

AUTO

 

come on during warm-up period.This is normal.)

2 HR

 

4 HR

 

Step 3: Aim sensor head in desired position. NOTE: Maintain air

 

 

 

spacing between lamps and sensor head at least 1”. Make

 

 

sure sensor head is positioned with control switches facing

 

 

towards the ground.

 

O

Step 4: Walk across the detection zone at the farthest distance you

 

 

 

wish your detector to detect motion.

 

 

Step 5: Adjust sensitivity until you get desired results. For more range, aim sensor head slightly upwards. For less range, aim sensor head slightly downward. Lights will turn off four seconds after all motion stops.

Step 6: Move slide switch to four MIN (AUTO mode) or to one of the two NIGHT TIME ON settings. At dusk, lights will operate in the AUTO or NIGHT TIME ON settings. (Refer to page 6 for detailed descriptions of the different modes.)

House code selections on sensor head (O)

The sensor and indoor alarm/lamp module must be set to the same house code number for the system to work properly. When the outside motion sensor is activated, the indoor alarm will sound (in 1, 2, 3, or 4 chirp intervals depending on the house code selected).

If there is a lamp plugged into the module, the lamp will come on and stay on for 10 min- utes. More than one sensor can be used to activate an indoor alarm/lamp control mod- ule. All outdoor sensors set to the same house code will activate ALL indoor alarm/lamp modules that are set to the same house code number.

Indoor alarm/lamp control module operation guide (P)

 

Switch setting:

Tones:

Indoor lamp:

 

 

Number of beeps based

 

 

AUTO

on house code setting

Daytime:Off

 

(fixture house code must

Nighttime: On for

 

 

be same as module

10 minutes

 

 

house code)

 

 

 

 

 

 

 

Number of beeps based

 

 

LAMP ON

on house code setting

 

 

(fixture house code must

On

 

 

be same as module

 

 

 

house code)

 

 

 

Number of beeps based on

When Mode of Operation switch is

 

 

house code setting of the

moved, lamp stays on 10 minutes .

 

TEST

Lamp will turn on for 10 minutes

 

fixture (fixture house code

 

at night if motion is detected. If fix-

 

 

does not have to be same

ture detects motion at Night or Day

 

 

as module house code)

alarm will chime.

 

 

 

 

OFF

Off (No tones)

Off (No light)

 

 

 

 