English

20Technical data

Factory settings

To minimize the need for adjustment, the factory settings include popular display stan- dards. Picture size and centering are automatically adjusted if any of these display stan- dards is detected. All the factory presets may be overwritten by adjusting the user controls. The monitor is capable of automatically storing up to 15 additional display stan- dards. The new display information must differ from any of the existing display standards by at least 1kHz for the horizontal scan frequency or 1Hz for the vertical scan frequency or the sync signal polarities must be different.

The VGA D-shell socket

Pin assignment

Connection

Signal

Connection

Signal

1

Red

9

not used

 

 

 

 

2

Green

10

Sync ground

 

 

 

 

3

Blue

11

Ground

 

 

 

 

4

Ground

12

Bidirectional data (SDA, DDC1/2B)

 

 

 

 

5

CPU host

13

Horizontal synchronization

 

ground

 

 

6

Red ground

14

Vertical synchronization

 

 

 

 

7

Green ground

15

Data timing (SCL, DDC2B)

 

 

 

 

8

Blue ground

 

 

 

 

 

 

The ELSA ECOMO 530 issues analog signals in accordance with the requirements of directive RS-170. The synchronization information is sent separately.

Video input connection to an

Apple Macintosh computer

Your ELSA monitor can be connected to a Macintosh computer. The graphics output port of the Macintosh has a 15-pin connector. To match up with the monitor’s VGA connector you require a suitable adapter. Contact your retailer for details.

ELSA ECOMO 5 30

Page 26
Image 26