M30870T-EPB User’s Manual 2. Setup
REJ10J0482-0300 Rev.3.00 February 16, 2006
2.9.1 Connecting to a 100-pin LCC Socket
When connecting the emulation probe to a 100-pin LCC socket (Yamaichi Electronics Co., Ltd.: IC61-1004-051 etc.) on the
user system, following the procedure below.
(1) Attach the CN2 side of the M30870T-EPB to the CN2 side of the M30800T-PTC.
(2) Attach the M30800T-PTC to the 100-pin LCC socket.
Figure 2.8 Connecting to a 100-pin LCC socket
CAUTION
Notes on Connecting the User System:
Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulator
and user system.
The small connectors of the M30870T-EPB and M30800T-PTC are guaranteed for only 50 insertion/removal
iterations.
For purchasing the IC61-1004-051 or for technical information, contact Yamaichi Electronics Co., Ltd.
http://www.yamaichi.co.jp/e/index.shtml
100-pin LCC socket
M3T-FLX160-EPB
M30870T-EPB
CN2 side
(1)
No. 1 pin
(2)
M30800T-PTC
User system
Page 30 of 104