Revolabs 03-HDEXEC4CN, 03-HDEXECEU, 01-HDEXEC4 Serial Command & Return Strings, String Table

Models: 01-HDEXEC 03-HDEXECEU 03-HDEXEC4CN 01-HDEXEC4 03-HDEXECJP & 03-HDEXEC4JP 03-HDEXEC4EU 03-HDEXECCN

1 40
Download 40 pages 4.87 Kb
Page 19
Image 19

When using a control system, the microphone mutes can be configured to ―int. mute‖, which mutes the microphone audio inside of the base station, or ―ext. mute‖, which allows the control system to choose another location for the mute to take place. When ―ext. mute‖ is selected, the microphones will always pass audio no matter their mute state.

Note: Both a control system and DSP cannot be connected to a Base Station as a serial control processor at the same time. When using a control system, the DSP control must be done by the control system and not the Base Station.

Serial Command & Return Strings:

The Serial Strings of an Executive HD Base Station begin with the Argument and terminates with a Carriage Return. The Command String structure is as follows:

<Argument> <Command> ch <Channel #> <Value> <CR>

All variable changes to the microphone or Base Station will result in a Return String. A Return String will begin with ―val‖ and terminate with a Carriage Return. You will receive a Return String for every value change that has taken place in the microphones or base station including changes that are a result of the Command String sent to the Base Station. The Return String structure is as follows:

val <Command> ch <Channel #> <Value> <CR>

String Table:

The following table represents the serial syntax of the Executive HD system. Any command marked with an asterisk will only function if the Base Station has Gold Enabled by entering that systems unlock code. (See Revolabs HD Gold Control Panel)

Argument

 

Command

 

Channel#

Value

 

 

 

 

 

 

 

 

 

 

 

set

 

lock*

 

1-8 = ch 1-8

0

= Mic Lock Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A = All Mics

1

= Mic Lock On

 

 

 

set

 

mute

 

1-8 = ch 1-8

0

= Unmute Mic

 

 

 

 

 

 

 

B = All Mics

1

= Mute Mic

 

 

 

set

 

mute

 

A = Master Mute

0

= Master Mute Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

= Master Mute On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

= Master Mute Toggle

 

 

 

set

 

gain*

 

1-8 = ch 1-8

0

= 0db Absolute

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A = All Mics

1

= -0.5db Relative

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

= +0.5db Relative

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80-120 = -10db - +10db in 0.5db increments

 

 

 

 

 

 

 

 

 

 

 

set

 

pair*

 

1-8 = ch 1-8

1

= Activate Pairing

 

 

 

set

 

pwr*

 

1-8 = ch 1-8

0

= Power Off Microphone

 

 

 

 

 

 

 

A = All Mics

 

 

 

 

 

set

 

um

 

 

0

= UnMute @ Startup Off

 

 

 

 

 

 

 

 

1

= UnMute @ Startup On

 

 

 

 

 

 

 

 

 

 

 

set

 

tm

 

 

0

= TableTop Mute Off

 

 

 

 

 

 

 

 

1

= TableTop Mute On

 

 

 

 

 

 

 

 

 

 

 

 

- 19 -