CONNECTORS & INDICATORS:

RF Output: SMA connector epoxied to straight feed point antenna in compliance with FCC rules part 15C, 15.203. Specifications

Video: BNC female bulkhead mount

Audio1/2: RCA female bulkhead mount

Controls: Channel switch – momentary, toggles through modes/channels

Indicators: 8 channel LEDs that blink slowly in Standby mode

ENVIRONMENTAL: Operating Temp.: -20 to 70 ºC Storage: -30 to 85 ºC Humidity: 95% noncondensing

Powerup

At powerup, the unit will retrieve the last used channel, program the PLL with this channel, and display the channel by blinking the LED the same number as the channel number.

Displaying Current Channel

To display the current channel, press the pushbutton once and release. The current channel will blink. After approx. 5 seconds, the current channel will again blink.

Changing to a New Channel

To change to a new channel, press the pushbutton once and release. The current channel will blink. Press and release the pushbutton again before 5 seconds has elapsed and the channel will increment by 1 and the LED will blink the new channel. Repeat this step until the desired channel is reached, waiting for the blinking to stop each time before pressing the button again.

Once your desired channel is reached, wait 5 seconds until the LED again blinks your desired channel. Your new channel is now saved in memory.

8 CHANNELS ARE AVAILABLE IN 2.4 GHz RANGE.

www.rf-links.com

Copyright © 2000-2006 rf-links.com All Rights Reserved

NOTE:

Model XL-2000/2HAS 2 W RF POWER OUTPUT.

Model XL-2000/HHAS 5 W RF POWER OUTPUT.

Model XL-2000/HPHAS 10 W RF POWER OUTPUT Note:

RECEIVER HAS 8 MATCHING CHANNELS, CHANNEL SETTINGS FOR THE RECEIVER IS INTERNAL.