LAZER BOILING WATER UNIT: FAULT FINDING GUIDE.

LAZER BOILING WATER UNIT: FAULT FINDING GUIDE.

**It is strongly recommended that any REMEDY be carried out by a qualified service person**

SYMPTOMS

POSSIBLE CAUSE

REMEDY

1.The unit does not fill with water

2.The unit fills water to low level and does not heat

3.The unit boils continuously

4.The unit overflows

5.There is no water from the tap

There is no power supply There is no water supply The inlet strainer is blocked

Electronic Controller failure

Solenoid Valve failure

The Filter is blocked (If unit is supplied with an inlet water filter)

Thermal cut-out has tripped

Heating element failure

Electronic Controller failure Thermistor failure

Low Air Pressure

Electronic Controller failure Thermistor failure

Incoming water pressure is too high

Solenoid valve failure

Level probe failure

The unit did not fill with enough water

The tap diaphragm is disconnected from its spindle

Check the electrical supply. Check the water supply.

Check the Inlet Strainer, clean or replace.

Test the electronic controller.

Check resistance of the solenoid, replace if broken.

Check the filter, replace if blocked (see section 5E for re setting the filter)

Reset the thermal cut-out.

If the heating element is properly wired, then check its resistance. Replace if broken.

Test the electronic controller. Replace the thermistor.

Recalibrate the unit (see section 5F sub section v) for how to recalibrate the unit

Test the electronic controller. Replace the thermistor.

Reduce incoming water pressure.

Turn the unit off. If water still overflows, replace the solenoid valve. Clean the level probe

Replace the level probe

See 1. & 2. above.

Drain water out of the unit (see paragraph 6 on page 4).

When unit is empty, disassemble and repair the tap.

10.

Page 10
Image 10