Rheem 316937A warranty Operation, Specification, H. Tap Outlet, J. Electrical Requirements

Models: 316937A

1 12
Download 12 pages 4.99 Kb
Page 5
Image 5
H. TAP OUTLET

H. TAP OUTLET

4. OPERATION

To prevent damage during transport the

When the installation is complete, first turn on

tap is wrapped and placed inside the

carton.

the water supply before switching on the

The tap is connected to the tap extension

power. The unit is programmed to

by a chrome-plated nut and tightened

automatically operate 24 hours a day, 7 days

using a 29 mm AF spanner.

a week. It is highly recommended for the user

J. ELECTRICAL REQUIREMENTS:

to program the timer (if the unit supplied has

one), as this will increase the life of the unit,

WARNING:

and consume less power (see Section 5 for

how to program the timer).

If this boiling water unit is to be installed

The electronic controller constantly monitors

in a newly constructed building, ensure

and controls the water level and water

that all electrical tests including

temperature to optimise the boiling wate

insulation tests have been performed

delivery.

prior to plugging in and switching on

 

your new Boiling Water Unit. Failure to

 

do so could damage the electronics.

 

220 –240 Volts AC, 50 Hz, Single Phase

10 Amps on 3, 5, 7.5,10 & 15 litre models

15 Amps on 25 litre model

20 Amps on 40 litre model

A flexible cord complete with a plug is supplied on all 3, 5, 7.5, 10 and 15 Litre models. Do not loosen the cord grip or pull excess cord into the Lazer. If the supply cord of this unit is damaged, it must be replaced by the manufacturer or a qualified service person.

The 25 and 40 litre models must be installed with fixed wiring. A means of disconnection from all active (phase) conductors of the power supply must be incorporated during installation in accordance with the wiring rules.

Operation based on an inlet water

temperature of 18ºC

Lazer

Approx Recovery

Approx. Time to heat

Litres / Hour

full Capacity

Size

 

(in minutes)

 

 

 

3.0 L

17.5

12

 

 

 

5.0 L

21

15

 

 

 

7.5 L

21

22

10 L

21

29

15 L

21

40

 

 

 

25 L

33

40

 

 

 

40 L

41

50

 

 

 

SPECIFICATION

 

3 Litre

5 Litre

7.5 Litre

10 Litre

15 Litre

25 Litre

40 Litre

Classic Series

 

 

 

 

 

 

 

Approx Weight (kg) Empty

6

8

9

10

15

17

19

Approx Weight (kg) Full

10

15

19

22

34

47

67

Minimum Water Pressure kPa

50

50

50

50

75

75

100

Maximum Water Pressure kPa

1000

1000

1000

1000

1000

1000

1000

Element Size kW

1.8

2.4

2.4

2.4

2.4

3.6

4.6

 

 

 

 

 

 

 

5.

Page 5
Image 5
Rheem 316937A warranty Operation, Specification, H. Tap Outlet, J. Electrical Requirements