Rheem Commercial Power Direct Vent Water heater installation instructions Venting

Models: Commercial Power Direct Vent Water heater

1 28
Download 28 pages 32.61 Kb
Page 8
Image 8

Installation

!WARNING

NEVER use open flame to test for gas leaks, as bodily injury or property damage could result.

PRESSURE TESTING THE GAS SUPPLY SYSTEM — The water heater and its manual gas shut-off valve MUST be disconnect- ed from the gas supply piping system during any high pressure testing of that system at pressures in excess of 1/2 psi (14” w.c. / 3.5 kPa).

The water heater MUST be isolated from the gas piping system by closing the manual gas shut-off valve during any pressure test- ing of the gas supply piping at pressures equal to or less than 1/2 psi (14” w.c. / 3.5 kPa).

5.VENTING —

!WARNING

The water heater must be vented to the outdoors as described in these instructions. DO NOT connect this water heater to an existing Vent or Chimney it must be vented separately from all other appliances.

!WARNING

Failure to properly vent the water heater to the outdoors as outlined above and in the following section can result in unsafe operation of the water heater causing bodily injury, explosion, fire or death.

!WARNING

To avoid the risk of fire, explosion or asphyxiation from carbon monoxide, NEVER operate this water heater unless it is properly vented and has an adequate air supply for proper operation. The vent pipe must overlap a minimum of ½" on each connection. It is important that the vent pipe engages fully into any pipe fitting and be kept in that position until the adhesive has fully cured. DO NOT drill or punch holes in the plastic pipe or fittings.

NOTICE: This unit can be vented using only the following recommended pipe material. Use only 3- or 4-inch diameter pipe.

PVC (Schedule 40, ASTM D-1785)

CPVC (Schedule 40, ASTM F-441)

ABS (Schedule 40, ASTM D-2661)

The fittings, other than the VENT TERMINAL, should be equiva- lent to the following:

PVC (Schedule 40 DWV, ASTM D-2665)

CPVC (Schedule 40 DWV, ASTM F-438)

ABS (Schedule 40 DWV, ASTM D-2661)

The unit may be vented horizontally through a wall or vertically through the roof. Pipe runs must be adequately supported along both vertical and horizontal runs. Maximum unsupported span is recommended to be no more than 4 feet. It is imperative that the first hanger be located on the horizontal run immediately adjacent to the first 90-degree elbow from the vertical rise or at the blower outlet in the case of a horizontal blower position. Support method used should isolate the vent pipe from floor joists or other structural members to help prevent the transmission of noise and vibration. Do not support, pin or otherwise secure the vent- ing system in a way that restricts the normal thermal expansion and contraction of the chosen venting material.

If the water heater is being installed as a replacement for an existing power vented water heater, a thorough inspection of the existing venting system must be performed prior to any installation work. Verify that the correct materials, as detailed above have been used, and that the mini- mum or maximum vent length and terminal locations as detailed in this manual have been met. Carefully inspect the entire venting system for any signs of cracks or fractures, particularly at the joints between elbows or other fittings and the straight runs of vent pipe. Check the system for signs of sagging or other stresses in the joints as a result of misalignment of any components in the system. If any of these conditions are found, they must be corrected in accordance with the venting instructions in this manual before completing the installation and putting the water heater into service.

VENT PIPE CONNECTION —

Outlet

Vent Connection

Inlet

Vent Connection

Figure 5. Vent Pipe Connection Locations

The blower assembly is preinstalled at the factory, so all that is required for connecting the vent system is attaching the vent pipe to the blower and the PVC Tee. Before starting the vent installation, careful planning should be given to the routing and termination of the vent pipe.The length of the vent pipe (inlet and outlet) should be kept to a minimum. Also, see page 10 & 12 for vent terminal placement.The GP100-150 & GP100-200 model can be vented using either 3 inch or 4 inch Schedule 40 PVC pipe and fittings.

To use 3 inch PVC, you can connect directly to the blower outlet (rubber coupling provided for outlet connection) and PVC Tee. Make sure that clamps on rubber coupling are tight, after the pipe is installed. The inlet vent pipe should be cemented into the PVC Tee.

If 4 inch PVC pipe is going to be used, then it will be necessary to have a short piece ( at least 3 inches long ) of 3 inch PVC pipe to join into the coupling and tee. Then a 4 X 3 reducer would need to be joined to the short piece of pipe, so that the 4 inch pipe could be used.The 4 inch pipe will then need to be stepped back down, using a 4 X 3 reducer, to 3 inch PVC. To install the vent terminals, a short length of 3 inch (maximum of 16 inches long) pipe will need to be used. (Refer to Figure 9b on page 10.)

The GP100-250 model can only be vented using 4 inch Schedule 40 PVC pipe and fittings. The 4 inch pipe can be connected directly to the blower coupling and 4 inch tee.

Page 8
Image 8
Rheem Commercial Power Direct Vent Water heater installation instructions Venting

Commercial Power Direct Vent Water heater specifications

The Rheem Commercial Power Direct Vent Water Heater is engineered to meet the demanding needs of commercial applications, providing reliable and efficient hot water for various business environments. With a focus on performance, efficiency, and durability, this water heater stands out in the competitive landscape of commercial water heating solutions.

One of the key features of the Rheem Commercial Power Direct Vent Water Heater is its direct vent capability. This innovative design allows for installation in confined spaces while optimizing exhaust methods. The direct vent system enables the heater to draw air from outside the building for combustion, ensuring safe operation, reducing risk of backdraft, and maintaining indoor air quality.

The water heater is powered by either natural gas or propane, accommodating diverse fuel supply preferences. With a range of storage capacities, it can cater to small and large businesses, from restaurants to industrial facilities. The product’s high recovery rate ensures that it can meet peak hot water demands, making it an ideal solution for facilities with fluctuating hot water usage.

Equipped with advanced technology, the Rheem Commercial Power Direct Vent Water Heater features a state-of-the-art electronic control system that allows for easy temperature adjustments and monitoring. This interface ensures precise temperature control, so businesses can consistently deliver hot water at the required temperatures.

Durability is a hallmark of this water heater, which incorporates premium-grade components and materials. The tank is constructed with a glass-lined steel design that enhances resistance to corrosion, while also supporting longevity. Additionally, it features robust insulation that reduces heat loss, improving energy efficiency and lowering operating costs.

Another notable characteristic is the inclusion of a high-efficiency burner that maximizes fuel utilization, promoting energy savings and reducing emissions. The heater also complies with various energy standards, making it a sustainable choice for environmentally conscious businesses.

Installation and maintenance are streamlined with the Rheem Commercial Power Direct Vent Water Heater. Its compact design and versatile venting options allow for flexible placement. Furthermore, the unit is designed for easier access to critical components, making routine service and maintenance uncomplicated.

Overall, the Rheem Commercial Power Direct Vent Water Heater represents a fusion of efficiency, ease of use, and advanced technology, making it a smart investment for commercial establishments needing reliable hot water solutions. Whether in kitchens, manufacturing plants, or commercial offices, this water heater is engineered to deliver performance and peace of mind.