Rheem AP15121-1, HP50RU, HP50RH, HP40RU, 92-103234-02 Cavity Insert Instructions

Models: HP50RH HP50RU 92-103234-02 HP40RU AP15121-1

1 20
Download 20 pages 58.36 Kb
Page 18
Image 18

Cavity Insert Instructions

The following instructions are intended for qualified service personnel ONLY, and should only be done when necessary.

In order to replace the ECO,thermistor or heating element, remove the cavity insert crossbar by following the instructions below:

Turn off the power to the water heater.

Remove the jacket access panel(s) and insulation. See page 20.

Rotate the crossbar up and down until it breaks away from the remainder of the cavity insert. (See illustration to the left)

Discard the crossbar. It cannot and need not be replaced.

Replace the ECO,thermistor and/or element as necessary.

Replace the insulation and jacket access panel(s) before turning on the power to the water heater.

NOTICE: The cavity insert crossbar is necessary for the manufacturing process only. The removal of the crossbar will not interfere with the operation of the water heater.

18