Standard Operation:

Wireless Monitor Status LED’s

 t 5IFXJSFMFTTNPOJUPSSFDFJWFTEBUBGSPNUIFHFOFSBUPS every 10 minutes and displays the generator status through 3 LED’s.

t 1SFTTJOHUIFSYSTEM UPDATE button will provide current generator status by flashing the status LED’s. When pressed, all 3 LEDs will flash until the generator status is received.

NOTICE Generator control panel must be in AUTO mode or no communication with monitor will occur.

t *OPSEFSUPDPOTFSWFQPXFSBOEUPFYUFOECBUUFSZMJGF the LED’s are not lit continuously; instead they are briefly flashed as indicated below.

NOTICE During the weekly exercise cycle, the generator will run for 20 minutes, but it will not supply power to the home. During the exercise cycle, the monitor will continue blinking the GENERATOR READY green LED.

 t (&/&3"5033&"%:8IFOBDUJWFUIFHSFFO-&%XJMM flash once every 7 seconds. The green LED indicates that the generator is in AUTO mode and that it is ready to run in the event of a loss of utility power.

 t (&/&3"503108&38IFOBDUJWFUIFHSFFO-&%XJMM flash every 7 seconds. The green LED indicates that the generator is supplying power.

 t 4&37*$&/&&%&%8IFOBDUJWFUIFSFE-&%XJMMGMBTI in a sequence that corresponds to the service code. For example, when Low Frequency scrolls across the control board, the red LED will flash 5 times with a 3 second pause between series of blinks until it is reset or the condition is corrected. When the red LED is lit, contact your nearest authorized service dealer.

NOTICE None of the conditions on the display unit can be cleared at the wireless monitor. All alerts must be cleared at the generator control panel.

NOTICE Service conditions will only be displayed on the basic monitor when the control board is placed in AUTO mode.

Other:

LED Lighting Codes

t #BUUFSJFT*OTFSUFEGENERATOR READY LED will light for 5 seconds.

t 8JSFMFTT$PNNVOJDBUJPO-PTUSERVICE NEEDED LED will flash 20 fast pulses, then pause for 5 seconds, and repeat the sequence until the communication has been restored.

NOTICE Communication lost issues can typically be resolved by moving the wireless monitor closer, within the home, to the standby generator.

t -JOLJOH&SSPSPS/PU-JOLFESERVICE NEEDED LED will light for 4 seconds, pause for 4 seconds, and repeat the sequence until a successful link is completed.

Installation Inspection

Before placing the generator system into service, inspect the entire installation carefully.

This completes the installation and start-up instructions. The operator’s manual provides full details on Operation, Maintenance and Troubleshooting for this generator system.