ACCESSORIES

ACCESSORY EQUIPMENT

 

 

 

 

 

Accessory

Model

Accessory

Description

Application

Model No.

Roofcurbs

 

RXSG-AAA08 (8" [203 mm] Height)

RSNA-B

RXSG-AAA14 (14" [356 mm] Height)

 

 

RXSG-AAA24 (24" [610 mm] Height)

Supply & Return Diffusers

RSNA-B

RXRN-BD15

 

 

 

Economizers (Downflow ONLY)

RSNA-B

RXRE-CAA30 (3 Position)

RXRD-CAM10 (Fully Modulating)

 

 

Fresh Air Damper

RSNA-B

RXRF-FAB1 (Motorized-35%)

RXRF-FAA1 (Fixed-35%)

 

 

Rectangular to Round Transition (Downflow)

RSNA-B

RXMC-CA02 (16" [406 mm] Ducts)

RXMC-CA03 (18" [457 mm] Ducts)

 

 

Filter Kit

RSNA-B

RXRY-B01

Low Ambient Control

RSNA-B

RXRZ-A18

High Pressure Control

RSNA-B

RXAB-A02

Low Pressure Control

RSNA-B

RXAC-A02

Sideflow Rectangular to Round Transition

RSNA-B

RXMC-BA01

LP Conversion Kits

RSNA-B

RXGJ-EP84W (White-Rodgers Gas Valve)

RXGJ-EP85H (Honeywell Gas Valve)

 

 

Canadian High Altitude Kit (for Natural Gas only*)

RSNA-B

RXRX-AH01

*If a particular unit is to be converted to operate on LP (propane) for elevations above 2000 ft. [609.6 m] in Canada, the existing Natural Gas to LP Conversion Kits for the subject models already contain the necessary orifices and instructions to de-rate the input for 2000-4500 ft. [609.6-1371.6 m] Canadian applications.

[ ] Designates Metric Conversions

COMMON SUPPLY/RETURN

CONCENTRIC AIR DIFFUSER

SUPPLY/RETURN DIFFUSER

Designed to convert a side by side or an over and under arrange- ment into a concentric distribution of air. The diffuser is flush mounted, completely insulated, assembled, and internally baffled to provide four way supply air distribution with a center return. To make the assembly complete and ready to fit into a 2' [0.61 m] x 4' [1.22 m] suspended ceiling grid, the diffuser includes adjustable supply louvers, hanging rings, anti-sweat gasket, and round flanges for use with flexible ducts.

Model No.

Diameter

Shipping Wt.

Dimension A

RXRN-

Inches [mm]

Lbs. [kg]

Inches [mm]

BD15

16 [406]

90 [40.82]

201/2 [521]

NOTE: The location of the combination supply and return diffuser should not exceed 10 feet [3.05 m] above the floor level for units @ 1000 CFM [472 L/s] or less and 12 [3.66 m] to 14 feet [4.27 m] above the floor level for units with CFM greater than 1000 [472 L/s]. If the diffuser is installed with a greater distance than recommended above, the supply air may become stratified above the required comfort area causing uncomforta- ble conditions.

AIRFLOW/PRESSURE DROP INFORMATION (INCHES W.C. [kPa])

Accessory

Approximate CFM [L/s]-Supply Air

1300 [614]

1575 [743]

1800 [850]

2200 [1038]

 

Plenum & Supply/Return Duct

.07 [.017]

.10 [.024]

.12 [.030]

.17 [.042]

Diffuser

.09 [.022]

.13 [.032]

.16 [.040]

.24 [.060]

Economizer

.06 [.015]

.09 [.022]

.11 [.027]

.17 [.042]

SUPPLY AIR/PERFORMANCE

Diffuser Airflow CFM [L/s]

Range of Throw Ft. [m]

800

[378]-1200 [566]

14 [4.27]-16 [4.88]

1600

[755]-2000 [944]

18 [5.49]-28 [8.53]

21

Page 21
Image 21
Rheem RSNA-B Series manual Accessory Equipment, Supply AIR/PERFORMANCE