GENERAL DATA—RSNA-B SERIES

GENERAL DATA—RSNA-B SERIES

NOMINAL SIZES 2-5 TONS [7.0-17.6 kW]

Model RSNA-B Series

B024JK

B030JK

B036CK

 

B036JK

Cooling Performance1

 

 

 

 

CONTINUED

Gross Cooling Capacity Btu [kW]

24,800 [7.27]

31,200 [9.14]

37,400 [10.96]

37,400 [10.96]

EER/SEER2

11.8/13

11.1/13

11.7/13

11.7/13

Nominal CFM/ARI Rated CFM [L/s]

800/800 [378/378]

1000/1000 [472/472]

1200/1200 [566/566]

1200/1200 [566/566]

ARI Net Cooling Capacity Btu [kW]

24,000 [7.03]

30,000 [8.79]

36,000 [10.55]

36,000 [10.55]

Net Sensible Capacity Btu [kW]

17,171 [5.03]

20,984 [6.15]

25,736 [7.54]

25,736 [7.54]

Net Latent Capacity Btu [kW]

6,829 [2]

9,016 [2.64]

10,264 [3.01]

10,264 [3.01]

Net System Power kW

2.04

2.7

3.07

3.07

Compressor

 

 

 

 

 

No./Type

1/Copeland Scroll

1/Copeland Scroll

1/Copeland Scroll

1/Copeland Scroll

Outdoor Sound Rating (dB)3

76

76

76

76

Outdoor Coil—Fin Type

Louvered

Louvered

Louvered

 

Louvered

Tube Type

Rifled

Rifled

Rifled

 

Rifled

Tube Size in. [mm] OD

0.375 [9.5]

0.375 [9.5]

0.375 [9.5]

0.375 [9.5]

Face Area sq. ft. [sq. m]

10.56 [0.98]

10.56 [0.98]

14.8 [1.37]

14.8 [1.37]

Rows / FPI [FPcm]

1 / 18 [7]

1 / 18 [7]

1 / 22 [9]

1 / 22 [9]

 

 

 

 

 

 

Indoor Coil—Fin Type

Louvered

Louvered

Louvered

 

Louvered

Tube Type

Rifled

Rifled

Rifled

 

Rifled

Tube Size in. [mm]

0.375 [9.5]

0.375 [9.5]

0.375 [9.5]

0.375 [9.5]

Face Area sq. ft. [sq. m]

5.54 [0.51]

5.54 [0.51]

5.54 [0.51]

5.54 [0.51]

Rows / FPI [FPcm]

2 / 15 [6]

2 / 15 [6]

2 / 15 [6]

2 / 15 [6]

Refrigerant Control

TX Valves

TX Valves

TX Valves

 

TX Valves

Drain Connection No./Size in. [mm]

1/0.75 [19.05]

1/0.75 [19.05]

1/0.75 [19.05]

1/0.75 [19.05]

Outdoor Fan—Type

Propeller

Propeller

Propeller

 

Propeller

No. Used/Diameter in. [mm]

1/22 [558.8]

1/22 [558.8]

1/22 [558.8]

1/22 [558.8]

Drive Type/No. Speeds

Direct/1

Direct/1

Direct/1

 

Direct/1

CFM [L/s]

2500 [1180]

2500 [1180]

2700 [1274]

2700 [1274]

No. Motors/HP

1 at 1/5 HP

1 at 1/5 HP

1 at 1/5 HP

 

1 at 1/5 HP

Motor RPM

1075

1075

1075

1075

Indoor Fan—Type

FC Centrifugal

FC Centrifugal

FC Centrifugal

 

FC Centrifugal

No. Used/Diameter in. [mm]

1/9x7 [228.6x177.8]

1/10x9 [254x228.6]

1/10x9 [254x228.6]

1/10x9 [254x228.6]

Drive Type/No. Speeds

Direct/2

Direct/3

Direct/3

 

Direct/3

No. Motors

1

1

1

1

Motor HP

1/4

1/2

1/2

1/2

Motor RPM

1075

1075

1075

1075

Motor Frame Size

48

48

48

48

 

 

 

 

 

 

Filter—Type

Field Supplied

Field Supplied

Field Supplied

 

Field Supplied

Furnished

No

No

No

 

No

(No.) Size Recommended in. [mm]

(1)1x20x20 [25x508x508]

(1)1x24x24 [25x610x610]

(1)1x24x24 [25x610x610]

(1)1x24x24 [25x610x610]

 

 

 

 

 

 

Refrigerant Charge Oz. [g]

69.6 [1973]

72 [2041]

83.2 [2359]

83.2 [2359]

Weights

 

 

 

 

 

Net Weight lbs. [kg]

370 [168]

379 [178]

392 [178]

392 [178]

Ship Weight lbs. [kg]

379 [172]

388 [176]

401 [182]

401 [182]

See Page 10 for Notes.

 

 

[ ] Designates Metric Conversions

7

Page 7
Image 7
Rheem RSNA-B Series manual General Data-Rsna-Bseries, NOMINAL SIZES 2-5TONS 7.0-17.6kW, Continued

FAQ

What are the nominal sizes for the Rheem RSNA-B Series?

The nominal sizes for the Rheem RSNA-B Series range from 2-5 tons and 7.0-17.6kW.

What is the EER/SEER rating for the RSNA-B Series models?

The EER/SEER rating for the RSNA-B Series models is 11.7/13.

What is the refrigerant control used for the RSNA-B Series?

The refrigerant control used for the RSNA-B Series models is TX Valves.