Riccar RSBH-SB, RSBHP-C Problem Solving Guide, Frequently Asked Questions, Possible Solution

Models: RSBH-SB RSBHP-C RSBH-O RSBH-C RSBHP-O

1 13
Download 13 pages 41.93 Kb
Page 11
Image 11
Problem Solving Guide

Problem Solving Guide

Frequently Asked Questions

Q: I turned the heater on, but nothing is happening yet.

A:Make sure the heater temperature is set above your room’s current temperature on the thermostat dial. After 2 minutes the air inside the heater will be warm and the heater fan will begin to operate.

Q: Why is the heater still running after I turned down the thermostat?

A:You will hear the heater fan running after you have turned the thermostat down. This allows the heater to cycle the remaining heat into the room and helps to cool down the heating element which protects the unit’s components from overheating.

Q: Can I use the heater to heat multiple rooms at the same time?

A:The heating capability will depend on your floor plan, the insulation and the room size. Ceiling fans will help circulate heat. Placing the heater in a central location will also help move heat between rooms.

Q: Will my heater work in areas without insulation?

A:The heater will work in garages, basements and unfinished rooms. However, bear in mind the effectiveness of your heater depends on how well the area is sealed and insulated. As with any heater, the better the walls, floor and ceiling are sealed and insulated, the more effective the room will be heated.

Q: Can I use multiple heaters in an area?

A:Depending on the size of the area, you may wish to use multiple heaters. Multiple heaters may be used. Your heater is rated 12 amps so each heater must plug into an independent 15 amps or greater circuit.

18

 

 

 

Problem Solving Guide

 

 

 

 

 

 

Troubleshooting

 

 

 

 

Problem

 

Possible Solution

 

 

 

The zone heater’s airflow

 

• Make sure the filter is clean.

 

has been reduced.

 

• Check the back intake for any objects that could obstruct airflow.

 

 

 

• If the heater’s airflow is still diminished or has stopped, contact your

 

 

 

Riccar Authorized Retailer.

 

 

 

 

 

The zone heater stays on

 

• This is a normal function of the heater. During this time, the heater is

 

after I turn the thermostat

 

cycling the remaining heat into the room and is cooling the heating ele-

 

down.

 

ment down.

 

 

 

 

 

 

 

• Make sure the heater is plugged directly into an unused, grounded 120

 

The zone heater will not

 

volt, 15 amps or higher circuit receptacle.

 

turn on.

 

• Make sure the amber light displays on the front of the unit indicating

 

 

 

the heater is plugged into an electrical outlet, turned on and is receiving

 

 

 

power.

 

 

 

 

 

 

 

• Make sure the heater temperature is set above your room’s

 

The circuit breaker

 

current temperature

 

button popped out.

 

• Press the on/off switch to Off.

 

 

 

• Unplug the power cord.

 

 

 

• Push the circuit breaker button to reset.

 

 

 

• Plug the power cord directly into an unused, grounded 120 volt, 15

 

 

 

amps or higher circuit receptacle.

 

 

 

• Press the on/off switch to On.

 

 

 

• If the circuit breaker trips a second time, return the heater to an

 

 

 

Authorized Riccar Retailer.

 

 

 

 

 

 

The zone heater tipped

 

 

 

 

over on its side and shut

 

• This is a normal safeguard function of the heater. Return the heater to

 

off, but the fan is still

 

its normal upright operating position and the power will resume.

 

running.

 

 

 

 

 

 

 

 

 

The programmable

 

 

 

 

thermostat doesn’t light up.

 

• Slide the On/Standby switch to On.

 

 

 

 

 

Any other service should be done by an Authorized Service Representative.

Service 1-888-6-RICCAR

To locate your nearest retailer, visit our website at www.riccar.com