Problem

Cause

Remedy

 

 

 

 

 

 

 

 

 

Sensor Cleaning

 

D4

 

 

There are visible

 

Activate [Pixel Mapping] from

 

 

 

 

 

defects in a

 

 

 

Raise the mirror up and open the shutter when cleaning the

 

 

 

the D4 menu.

 

 

 

 

captured image, or

There are

 

 

 

 

It takes about 30 seconds to

 

 

CMOS sensor with a blower.

 

 

 

parts in the display

defective pixels in

 

 

 

 

 

correct the defective pixels, so

 

 

1 Turn the camera off and remove the lens.

 

 

 

monitor that do not

the CMOS sensor.

be sure to install a fully charged

 

 

 

 

 

light up or remain

 

 

 

 

 

 

 

battery.

 

 

 

 

 

lit.

 

 

 

 

2 Turn the camera on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 Select [Sensor Cleaning] in D4 menu and press

 

 

 

 

 

 

 

D.

 

 

 

 

 

 

 

 

The [Sensor Cleaning] screen appears.

 

 

 

 

 

 

 

 

4 Select [Mirror Up] and press E.

 

 

 

 

 

 

 

 

The mirror pops up and the grip lamps blink.

 

 

 

 

 

 

 

 

5 Clean the CMOS sensor with a blower.

 

6

 

 

 

 

 

 

Appendix

 

 

 

 

 

 

6 Turn the camera off.

 

 

 

 

 

 

 

The mirror automatically returns to its original position.

 

 

 

 

 

 

u Caution

 

 

 

 

 

 

 

• Never use a spray blower or a blower with a brush. The

 

 

 

 

 

 

 

CMOS sensor may be damaged. Do not wipe the CMOS

 

 

 

 

 

 

 

sensor with a cloth.

 

 

 

 

 

 

 

 

• Do not put the tip of the blower inside the lens mount area. If

 

 

 

 

 

 

 

the power is turned off, this may cause damage to the shutter,

 

 

 

 

 

 

 

CMOS sensor and the mirror.

 

 

 

 

 

 

 

 

• When the battery level is low, the message [Not enough

 

 

 

 

 

 

 

battery power remaining to clean sensor] is displayed on the

 

 

 

 

 

 

 

monitor. Install a fully charged battery. If the battery capacity

 

 

 

 

 

 

 

becomes low during cleaning, a warning beep will sound. In

 

 

 

 

 

 

 

this case, stop cleaning immediately.

 

90