Ricoh FV-L030B1 manual 30/32

Models: FV-L030B1

1 32
Download 32 pages 44.18 Kb
Page 30
Image 30

Command No.

 

 

 

 

 

 

 

 

 

 

Command Descriptions

 

A0H:

 

[Pixel defect correction mode] Initial data: PDC0[7..0] = 0

 

PDC0[70]

 

D[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

 

D6

D5

D4

 

D3

D2

D1

 

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7:

 

Write the correction index

 

0 ￿ 1

 

 

 

 

 

 

*Writes the coordinates of the command, A2 to A5, to the index number specified by the

 

 

 

 

 

command A1.

 

 

 

 

 

 

 

 

 

 

 

*This bit is cleared to “0” automatically after the execution of the command.

 

 

 

D6

 

Read the correction index

 

0 ￿ 1

 

 

 

 

 

 

*Reads the coordinates of the index number specified by A1 and loads them to the command,

 

 

 

 

 

A6 to A9.

 

 

 

 

 

 

 

 

 

 

 

 

*This bit is cleared to “0” automatically after the execution of the command.

 

 

 

D5:

 

Save to the EEPROM

 

 

0 ￿ 1

 

 

 

 

 

 

*Writes the coordinates of all 16 index numbers to the EEPROM.

 

 

 

 

 

 

*This bit is cleared to “0” automatically after the execution of the command.

 

 

 

D4 to D2

No function

 

 

 

 

Always set as “000”

 

 

 

D1

 

Correction indices display

 

0: OFF

1: ON

 

 

D0

 

Pixel defect correction

 

 

0: OFF

1: ON

 

 

 

 

A1H:

 

[Pixel defect correction index number]Initial data: PDC1[7..0] = 0, data range: 0 to 15

 

PDC0[70]

 

D[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

 

D6

D5

D4

 

D3

D2

D1

 

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7 to D4:

No function

 

 

 

 

Always set as “0000”

 

 

 

D3 to D0:

Index number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A2H:

 

[PDC X coordinate (Write)]

 

 

 

 

 

 

 

PDC_WX[70]

 

Initial data: PDC_WX[15..0] =0, data range: 0 to the number of horizontal pixels of the effective area

A3H

 

Set the X coordinate of pixel defect.

 

 

 

 

 

PDC_WX[158]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A4H:

 

[PDC Y coordinate (Write)]

 

 

 

 

 

 

 

PDC_WY[70]

 

Initial data: PDC_WY[15..0] = 0, data rage: 0 to the number of vertical pixels of the effective area

A5H

 

Sets the Y coordinate of pixel defect.

 

 

 

 

 

PDC_WY[158]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A6H:

 

[PDC X coordinate (Read)]

 

 

 

 

 

 

 

PDC_RX[70]

 

Initial data: PDC_RX[15..0] = 0, data rage: 0 to the number of vertical pixels of the effective area

A7H

 

The X coordinate of pixel defect will be loaded when reading.

 

PDC_RX[158]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A8H:

 

[PDC Y coordinate (Read)]

 

 

 

 

 

 

 

PDC_RY[70]

 

Initial data: PDC_RY[15..0] = 0, data rage: 0 to the number of vertical pixels of the effective area

A9H

 

The Y coordinate of pixel defect will be loaded when reading.

 

PDC_RY[158]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C0H: [70]

 

[Lower limit of the electronic shutter] Initial data: 1; data range: 0 to 4,095

 

C1H: [70]

 

Sets the upper limit of the electronic shutter in horizontal lines when using AE (auto exposure).

 

 

 

 

C2H: [70]

 

[Upper limit of the electronic shutter] Initial data: 4,095; data range: 0 to 4,095

 

C3H: [70]

 

Sets the upper limit of the electronic shutter in horizontal lines when using AE (auto exposure).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FVL030B1

30/32

User’s Guide Rev. 1.01

 

Page 30
Image 30
Ricoh FV-L030B1 manual 30/32